SN/T 5242-2020 in English
VALIDTextiles for import and export Determination of germanium-Inductively coupled plasma mass spectrometry method
- Issued on:2020-08-27
- Implemented on:2021-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$127.00
Introduction
Analysis of the core content of the standard
This standard uses inductively coupled plasma mass spectrometer as the core detection equipment, and uses microwave digestion pre-treatment technology to achieve trace detection of germanium in textiles. The method's lower limit of determination is 0.020 mg/kg, which meets the internationally accepted textile safety supervision requirements.
Comparison of key technologies
| Technical elements | This standard method | Conventional AAS method | Advantages |
|---|---|---|---|
| Detection limit | 0.020 mg/kg | 0.50 mg/kg | Sensitivity increased by 25 times |
| Analysis time | Single sample<5min | >15min | Efficiency increased by 3 times |
| Anti-interference ability | Mass number resolution | Spectral interference | Eliminate matrix effects |
Key points for standard implementation
Quality control case
When a laboratory used Bruker M90 ICP-MS to detect polyester samples, the signal intensity of 72Ge was increased by 40% by optimizing the nebulizer gas flow rate (0.90 L/min) and sampling depth (7.0 mm), and the RSD was controlled at <5%.
Digestion program optimization
The microwave digestion program recommended by the standard adopts a segmented heating strategy: 200℃ for 25 minutes, which not only ensures the complete decomposition of organic matter, but also avoids the loss of germanium volatilization. In actual application, the ratio of nitric acid (5mL) and hydrogen peroxide (3mL) needs to be adjusted according to the sample material.
Technology Evolution Analysis
Compared with the traditional method, this standard has three breakthroughs: 1) Introducing the 115In internal standard calibration system; 2) Using the nickel sampling cone to improve ion transmission efficiency; 3) Standardizing the 0.45μm aqueous membrane filtration process. These improvements stabilize the method recovery rate between 85-113%.
Implementation Recommendations
- Laboratories should regularly calibrate the injection efficiency of the nebulizer
- Different fabric types need to verify the completeness of digestion (cotton fabrics are recommended to increase the pre-digestion time)
- Standard solutions should be stored strictly under the conditions of 0-5℃/1 month

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SN 0283-1994 in English
\"Method for Inspection of Dichlorodipyridinol Residues in Exported Poultry Meat\"
1994-02-18 -

SN/T 0244-1994 in English
\"General Rules for Inspection and Certification of Imported Mechanical and Electrical Instruments\"
1993-08-01 -

SN/T 3482.1-2013 in English
Safety code for the inspection of packaging of infectious substance transported by air - Part 1: General specifications
2013-03-01