Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
cable length cable drum diameter ≥50 cable introduction core load detection cable 7-core cable major technical upgrades special tubes paper product
SY/T 6600-2020 in English

SY/T 6600-2020 in English

VALID

Petroleum drilling and production equipment-Loadable logging cable

  • Issued on:2020-10-23
  • Implemented on:2021-02-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $370.00
$359.00
Standard No: SY/T 6600-2020
Document status: VALID
Title in English: Petroleum drilling and production equipment-Loadable logging cable
Title in Chinese: 石油天然气钻采设备 承荷探测电缆
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2020-10-23
Implemented on: 2021-02-01
Superseding: SY/T 6600-2004 Load bearable detective cable
Professional Classification: SY-Oil & Gas
Related Keywords: cable length
cable drum diameter ≥50
cable introduction core
load detection cable
7-core cable
Related Topics: sy/t 6238.1
Oil and Gas Drilling Equipment
Natural Gas Analysis Equipment
charge
charge detection
charge detection
detection equipment
oil detector
Natural gas detection equipment
micro drilling rig
offshore oil drilling
device detection
oil detector
Oil Drilling Accessories
Petroleum gas
Natural gas testing equipment
Petroleum cable model
Natural gas detector spacing specifications
Natural gas probe detection cycle
Petroleum equipment monitoring
sy/t 6600
sy/t6600-2019
sy/t 7494-2020
sy/t 7466-2020
sy/t 7468-2020


Introduction

Core technical requirements of the standard

SY/T 6600-2020 clearly stipulates the exposed length of the conductor of the load detection cable: Insulation length ≥50mm, conductor exposed section ≥30mm (Clause 6.8.1). The insulation surface must be kept dry and clean (Clause 6.6.1.2).


Comparison of key test methods

Test items 2004 version requirements 2020 version updates
Insulation resistance test GB/T 3048.6-1994 GB/T 3048.5-2007Newly added temperature correction factor table
High temperature test Temperature requirements only Temperature + pressure dual indicators (deviation ±5%)
Residual elongation Unspecified calculation formula Added Formula (7) for precise calculation

Electrical performance test specifications

Capacitance measurement case: According to the requirements of clause 6.7, the capacitance value of each relative armor is measured at a frequency of 1kHz, and the calculation formula is C=Cmeasured/L (L is the cable length in kilometers). The measured capacitance value of a 7-core cable is 2.8μF/km, which meets the requirements of clause 5.7 of the standard.


Key points of standard update

  • Added the code of sealed cable (Clause 4.1.1)
  • Improved the requirements for helical stability of armored steel wire (Clause 5.5.5)
  • Introduced the low-temperature winding test (2m sample test at -15℃)

Implementation suggestions

  1. Temperature correction: Insulation resistance test needs to be converted to 20℃ according to the Kt coefficient table in Clause 6.6.3.2
  2. Arbitration test: Residual elongation test should ensure 250mm effective spacing (Clause 6.12.1)
  3. Transportation and storage: Cable drum diameter ≥50 times the outer diameter of the cable, flat laying is prohibited (Clause 8.1.2)

Sample only — not a preview of SY/T 6600-2020
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend