T/CAB 0069-2020 in English
VALIDTechnical requirements and test methods for rapid freezing of household refrigerators
- Issued on:2020-08-25
- Implemented on:2020-08-25
- File Format:PDF
- Delivery:Via email within 1~3 business days
$204.00
Introduction
Analysis of core technical requirements of the standard
| Key indicators | Pork tenderloin | Beef | Chicken thigh |
|---|---|---|---|
| Time passing through the ice crystal belt (≤min) | 30 | 30 | 30 |
| Quick freezing time (≤min) | 90 | 90 | 90 |
| 1 day juice loss rate (≤%) | 2.5 | 3 | 4.5 |
Technology Evolution and Standard Background
This standard establishes for the first time a quantitative indicator for time to pass the maximum ice crystal formation zone, requiring that the retention time of meat in the (-1~-5)℃ temperature zone does not exceed 30 minutes, which is more than 60% shorter than traditional freezing technology. By controlling the growth rate of ice crystals, mechanical damage to cells can be reduced, and the juice loss rate after 90 days of storage can be controlled to ≤10.5%.
Detailed explanation of key test methods
Meat pretreatment specifications
The test requires the use of an electronic balance to accurately weigh 400g±50g samples. Pork/beef must maintain a standard thickness of 4cm±1cm. Poultry must be processed within 2 hours after being killed alive. The thermocouple insertion position should be located at the geometric center point to ensure the accuracy of temperature measurement.
Juice loss rate test
The differential weight method is used for calculation: W(%)=(W0-W)/W0×100%, where W0 is the initial mass and W is the mass after thawing. During the test, absorbent paper should be used to absorb the surface juice, and a mass measuring instrument with an accuracy of 0.1g should be used.
Implementation recommendations for enterprises
- Quick freezing room design: It is recommended to adopt a multi-duct circulation system to ensure that the cooling rate in the temperature zone from -1℃ to -5℃ is ≥1℃/min
- Sensor layout: Temperature sensors are arranged at the geometric center and four corners of the quick freezing room to monitor the temperature distribution in real time
- Verification test: The new model needs to undergo repeatability tests on three prototypes, and it is recommended to add a total colony count test item
Analysis of innovation points of the standard
- Define the performance indicators of quick freezing rooms for the first time to promote technological upgrading of the industry
- Establish a correlation system between sensory evaluation of meat and physical and chemical indicators
- Introducing volatile basic nitrogen detection (detection limit 0.18mg/100g) as an auxiliary determination of freshness

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

T/SZS 2765-2022 in English
Shenzhen quality food—Starch sugar
2022-11-25 -

T/CIS 03001.1-2020 in English
Reliability of instrument or equipment—Verification and test method of the mean time between failures of complete machine
2020-03-01 -

T/CECS 10124-2021 in English
Hardening accelerating admixture for concrete
2021-03-22 -

T/CCOA 1-2019 in English
Flavor rapeseed oil
2019-01-15 -

T/CRACM 0002-2020 in English
Service evaluation of traditional Chinese medicine clinic
2020-06-15 -

T/ZJSEE 0002-2023 in English
Technical specifications for wheeled inspection robots in power distribution rooms
2023-03-23 -

T/CITS 0004-2023 in English
Technical requirements and testing methods for high-performance medical refrigerator
2023-02-28 -

T/CMA-HG013-2017 in English
Technical specification for 195/75R14 92S standard reference test tyre
1995-07-05 -

T/DYFIA 002-2022 in English
Dong yang powder dry
2022-11-15 -

T/CECS 10113-2020 in English
High strength lightweight aggregate
2020-11-11