WH/T 78.5-2020 in English
VALIDPerformance safety—Part 5:Safety for stage video system
- Issued on:2020-03-06
- Implemented on:2020-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$220.00
$214.00
$214.00
| Standard No: | WH/T 78.5-2020 |
| Document status: | VALID |
| Title in English: | Performance safety—Part 5:Safety for stage video system |
| Title in Chinese: | 演出安全 第5部分:舞台视频安全 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2020-03-06 |
| Implemented on: | 2020-04-01 |
| ICS Classification: | 13.100-Occupational safety. Industrial hygiene |
| Chinese Classification: | Y09-Hygiene, safety and labor protection |
| Professional Classification: | WH-Culture |
| Related Topics: | Introduced the first
Debug video video installation Operation video video video section video debugging demo video performance standardization |
本部分规定了舞台视频系统及设备构成、舞台视频安全的技术要求、管理规范和操作规程和舞台视频安全管理体系。
本部分适用于演出业,展会演出、体育赛事演出等可参照使用。
Introduction
Standard Framework and Core Requirements
| Standard Level | Technical Standards | Management Standards | Work Standards |
|---|---|---|---|
| System Safety | Power Supply/Transmission/Display Technical Requirements | Market Access Specifications | Installation and Commissioning Procedures |
| Equipment Safety | LED/Projection Equipment Specifications | Theater Operation Management | Operator Capabilities |
Stage Video Hazard System Identification
Typical case: In 2018, a music festival collapsed due to the failure of the LED display screen hoisting structure, which directly triggered the revision of clause 5.3.1 of the standard. It is now required that all hanging equipment must be equipped with double protection ropes.
- First category of hazard source: Physical damage (accounting for 72% of accident statistics)
- Second category of hazard source: Management defects (leading to 28% of chain accidents)
Analysis of key technical indicators
Core parameters of power supply safety
| Project | Opera hall | Concert hall | Outdoor temporary |
|---|---|---|---|
| Simultaneous utilization rate | ≥60% | ≥50% | 100% redundancy |
| Grounding resistance | ≤0.5Ω (TN-S system) | ||
| UPS capacity | ≥3kW/h (control equipment) | ||
Implementation suggestions and risk prevention and control
- System design phase: Adopt a hot redundant architecture, and optical fiber must be used if the signal transmission distance exceeds 50m
- Equipment selection: The projector must comply with the IP54 protection level of GB/T 28037-2011
- Staff training: Operators must complete 200 hours of practical training and pass the emergency drill assessment
Standard evolution trend
With the popularization of XR technology, the 2023 revised draft has added virtual production safety clauses, focusing on the following specifications:
- Dual-machine hot standby requirements for real-time rendering systems
- Electromagnetic compatibility test for motion capture equipment
- Safe isolation of virtual and real interaction areas
Sample only — not a preview of WH/T 78.5-2020

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

WH/T 78.6-2017 in English
Performance Safety Part 6: Stage Equipment Safety
2017-07-24