Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
cold water pipe standard mixed gas test persons
YD/T 4530-2023 in English

YD/T 4530-2023 in English

VALID

based distributed ENUM Technical requirements for Unified IMS(stage 2) system

  • Issued on:2023-12-29
  • Implemented on:2024-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $560.00
$544.00
Standard No: YD/T 4530-2023
Document status: VALID
Title in English: based distributed ENUM Technical requirements for Unified IMS(stage 2) system
Title in Chinese: 基于统一IMS(第二阶段)的分布式电话号码映射(ENUM)系统技术要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2023-12-29
Implemented on: 2024-07-01
Professional Classification: YD-Telecommunication
Related Topics: ims
number ims
ims data
ims number
distributed
Distributed+
Where is the signal peptide located?
Standards related to the division of telephone code segments

本文件规定了统一IMS(第二阶段)网络中分布式ENUM系统的的功能架构和接口信令要求,包括分布式ENUM系统组成、网元功能要求、接口功能要求及信令流程等。
本文件适用于统一IMS第二阶段(包括VoLTE IMS和固网IMS)的设计和研发。


Introduction

Technical Background and Evolution of Standards

As the IMS network evolves to the second phase, the traditional centralized ENUM system shows insufficient scalability in cross-operator interconnection scenarios. The distributed ENUM architecture proposed in this standard interconnects I-ENUM Server nodes to achieve efficient mapping between E.164 numbers and SIP URIs, and supports the deep integration of VoLTE and fixed-line IMS.


Core Architecture Analysis

Components Functions Deployment Requirements
IES Node Store cross-operator ENUM data and support NAPTR record translation Requires configuration of primary and backup IP addresses and support for NTP time synchronization
Carrier-grade ENUM Processes intra-domain queries and triggers cross-domain queries when failure occurs Can be set up together with IES
Interface System I1-I4 four types of interfaces for data synchronization and query Requires support for HTTP/SOAP/DNS protocol stacks

Key Function Implementation

5.2.1 Data Management Mechanism

IES adopts the broadcast synchronization mechanism to maintain data consistency across operators, supporting:

  • Incremental synchronization: newly added number segments are broadcast through NODE_JOIN_REQ
  • Real-time update: data modification triggers the MODDATA_BROCAST process
  • Safe deletion: The DELDATA process ensures data integrity

5.2.4 Authentication Design

Adopt two-factor authentication: operator ID+IP whitelist binding, abnormal access trigger:

  1. Direct rejection if source IP verification fails
  2. Automatic switching of primary and backup IPs (heartbeat cycle 1-3min)
  3. Overload protection threshold defaults to CPU50%/memory70%

Typical application scenarios

Cross-IMS domain call flow

Case: A user of operator A calls a user of operator B

1. The calling S-CSCF initiates a recursive query through the I3 interface
2. IES returns the SIP URI of domain B
3. An end-to-end SIP session is established (see Figure 10 for the signaling process)


Implementation recommendations

Deployment considerations

  • The IP and service identifier of the interconnected operator's IES node must be pre-configured
  • A hierarchical topology is recommended to control broadcast storms
  • The operation and maintenance interface must implement 4-level permission isolation

Operation and maintenance monitoring points

Monitoring items Indicators Alarm method
Data synchronization delay <500ms SMS/email
Query success rate >99.9% Sound and light alarm
Interface load Peak value<80% Web interface

Sample only — not a preview of YD/T 4530-2023
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • YD/T 839.3-1996 in English

    YD/T 839.3-1996 in English

    Filling and coating compounds for telecommunications cables and optical cables Part 3: Cold-applied filling compounds

    1996-04-04
  • YD/T 1277-2003 in English

    YD/T 1277-2003 in English

    Technical requirements and test methods for transmission of caller identification information in fixed telephone networks Part 1: Technical requirements

    2003-06-04
  • YD/T 1572-2010 in English

    YD/T 1572-2010 in English

    Testing methods for A10/A11 interfaces in 800MHz/2GHz cdma2000 digital Cellular mobile communication network

    2010-12-29
  • YD/T 0837.4-1996 in English

    YD/T 0837.4-1996 in English

    Test methods for copper-polyolefin-core insulated aluminum-plastic composite sheathed local copper-core cables

    1996-04-04
  • YD/T 2089-2010 in English

    YD/T 2089-2010 in English

    Technical requirements for internet content filtration product based on LAN gateway

    2011-01-01
  • YD/T 892-1997 in English

    YD/T 892-1997 in English

    Detail bill for express mail service

    1997-03-04
  • YD/T 769-2018 in English

    YD/T 769-2018 in English

    Central gel-filled loose tube optical fibre cables for outdoor application for telecommunication

    2018-12-21
  • YD/T 2465-2013 in English

    YD/T 2465-2013 in English

    Open Application Programming Interface (API) of Business Capabilities Based on Representational State Transfer (REST) Technology Weibo Business

    2013-04-25
  • YD 609-1993 in English

    YD 609-1993 in English

    Setup and Adjustment Limits for Mixed Digital-Analog Telephone Circuits

    1993-01-18
  • YD/T 2244-2020 in English

    YD/T 2244-2020 in English

    Testing requirements for security protection of telecommunication and Internet information service system

    2020-04-16