Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
power battery electrolyte power battery electrolyte introduction interpretation bisfluorosulfonylimide lithium salt imide lithium salt electrolyte compatibility jasmine aldehyde index requirements appendix a food category electromagnetic interference path loss
YS/T 1302-2019 in English

YS/T 1302-2019 in English

VALID

Bisfluorosulfonylimide lithium salt for power battery electrolyte

  • Issued on:2019-08-02
  • Implemented on:2020-01-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $210.00
$204.00
Standard No: YS/T 1302-2019
Document status: VALID
Title in English: Bisfluorosulfonylimide lithium salt for power battery electrolyte
Title in Chinese: 动力电池电解质双氟磺酰亚胺锂盐
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-08-02
Implemented on: 2020-01-01
Professional Classification: YS-Non-ferrous Metal
Related Keywords: power battery electrolyte
power battery electrolyte introduction interpretation
bisfluorosulfonylimide lithium salt
imide lithium salt
electrolyte compatibility
Related Topics: Power Battery
electrolyte
perylene imide
imide
imine
Power Battery
Amide desalination
Amide solubility
Amide solubility
Lithium digestion
Amide solubility
High energy power battery
Sulfur
Sulfonyl fluoride
Bisamide
Sulfonamide Synthesis
Sulfur+
Lithium aluminum lactam
Synthesis of sulfonamides
imine+
Lithium salt equipment
Lithium perfluorodibutylamine
Power battery 80
Double tube conductivity cell
battery electrolyte
electrolyte salt
Difluorosulfonyl
Lithium bisfluorosulfonyl imide
Dichlorosulfonimide
blood electrolytes
imide salt
Power battery electrolyte resistance test
Zhangqiang lithium salt
Hydroxyimine hydrolysis
Bischlorosulfonyl imide acid
Carbonyl fluoride quality
Lithium battery charging capability characterization method
Electrolytic manganese metal industry for lithium batteries
Bisfluorosulfonimide lithium salt quality
Bisfluorosulfonyl imide acid company
Quality of lithium salt
Bisfluorosulfonimide standard sample
Lithium fluoride quality standards
Solutions for low temperature charging of lithium batteries
Aviation power battery standards
ys/t1343-2019
ys/t 1302-2019
Lithium battery product quality
Industrial bischlorosulfonyl imide acid
Bischlorosulfonyl imide products

本标准规定了动力电池电解质双氟磺酰亚胺锂盐的技术要求、试验方法、检验规则、标志、包装、运输、贮存、质量证明书、订货单(或合同)要求。
本标准适用于动力锂电池电解质用双氟磺酰亚胺锂盐。


Introduction

Interpretation of the core content of the standard

This standard specifies the key technical indicators of bis(fluorosulfonyl)imide lithium salt (molecular formula: FNO4S2Li) as a power battery electrolyte:

Technical indicators Required values Test methods
Purity of main components ≥99.9% Calculation by difference method
Moisture content ≤0.005% GB/T 19282-2014
Heavy metal impurities ≤0.0002-0.0005% ICP-MS

Analysis of key technical requirements

1. Chemical composition control

The standard constructs a complete quality control system through main component + 26 impurity indicators:

  • The residue method is used to calculate the main component content (100% minus the total impurities)
  • Specially control corrosive impurities such as fluoride (≤0.01%) and chloride (≤0.001%)
  • DMC insoluble matter index (≤0.05%) to ensure electrolyte compatibility

2. Special detection methods

Fluoride detection case: Using the ion selective electrode method (Appendix A), the detection limit is 0.0005%, and TISAB buffer is required to eliminate ion interference.


Recommendations for the implementation of the standard

Key points for production control

  1. Raw material storage humidity needs to be <0.001%RH
  2. Packaging needs to be carried out in an inert gas protection environment
  3. Use double-layer packaging (HDPE pot + aluminum-plastic bag) to prevent moisture

Application precautions

This material decomposes in water to produce HF. Laboratory operations require:

  • Equipped with emergency flushing device
  • Use fluororubber gloves for protection
  • Waste needs to be neutralized with lime water

Analysis of standard evolution

Main improvements compared to the earlier version:

  • Added heavy metal indicators such as As/Cd/Pb (new in 2019 version)
  • Moisture requirement increased from 0.01% to 0.005%
  • Clarified summer cold chain transportation requirements

Sample only — not a preview of YS/T 1302-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend