YS/T 1525-2022 in English
VALIDMethods for chemical analysis of NiPt alloys—Determination of oxygen and nitrogen contents—Pulse-infrared absorption and thermal conductivity detectionetry
- Issued on:2022-09-30
- Implemented on:2023-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$194.00
本文件规定了镍铂合金中氧含量和氮含量的测定方法。
本文件适用于镍铂合中氧含金量和氮含量的测定。测定范围:0.0010%~0.020%。
Introduction
Interpretation of the core content of the standard
This document specifies the standard method for determining the oxygen (0.0010%~0.020%) and nitrogen (0.0010%~0.020%) content in nickel-platinum alloy using the pulse-infrared absorption method and the thermal conductivity detection method.
Comparison of Method Principles
| Detection Elements | Principle | Detection Limit | Applicable Content Range |
|---|---|---|---|
| Oxygen | Graphite crucible is melted to generate CO, infrared detection absorption peak | 0.1 μg/g | 0.0010%-0.020% |
| Nitrogen | Determination of thermal conductivity by nitrogen loading into thermal conductivity cell | 0.1 μg/g | 0.0010%-0.020% |
Key Operation Points
Sample Pretreatment
Soak in acetone for 5 minutes and then air dry naturally. Weigh the sample accurately to 0.0001 g (0.1g±).
Instrument Calibration
It is required to use 2 or more national steel standard samples (oxygen and nitrogen content 0.001%-0.02%) for calibration. The blank value must be controlled within <0.00005%.
Precision Control
For detailed repeatability limit (r) and reproducibility limit (R) data, please refer to Chapter 10 of the standard. When the oxygen content is 0.0042%, r=0.0024% and R=0.0025%.
Technology Evolution Analysis
Compared with the traditional chemical method, the innovations of this standard are:
- Simultaneous determination of oxygen and nitrogen
- Adopting modern equipment such as TC-400 oxygen and nitrogen analyzer
- The detection limit is reduced to 0.1 μg/g
Implementation suggestions
- The laboratory needs to be equipped with an oxygen and nitrogen analyzer with 1 hour stability RSD<2%
- It is recommended to verify the graphite crucible blank value regularly
- Pay attention to the melting temperature control for samples with high platinum content

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

YS/T 91-2002 in English
Aluminum and aluminum alloy plates and strips for bottle caps
2002-11-22 -

YS 41-1992 in English
Beryllium piece
1992-03-19 -

YS/T 750-2022 in English
Hot rolled titanium coil
2022-09-30 -

YS/T 85-1994 in English
Rhodium Matrix for Spectroscopic Analysis
1994-05-11 -

YS/T 13-1991 in English
High purity germanium tetrachloride
1991-04-26 -

YS/T 94-1996 in English
Copper sulfate (by-product of smelting)
1996-01-01 -

YS/T 410-1998 in English
Industry titanium foils for magnetic heads
1999-01-11 -

YS 45-1992 in English
General technical requirements for small train amusement machines
1992-05-22 -

YS 102-1992 in English
Lead and zinc smelting enterprise energy consumption
1992-03-17 -

YS/T 421-2000 in English
PS plate aluminum substrate for printing
2000-03-29