Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
medical device manufacturer medical device manufacturer yy/t medical device manufacturer bibliography medical device reusable medical device acute toxicity estimate oecd membrane water treatment devices energy consumption measurements
YY/T 0802-2020 in English

YY/T 0802-2020 in English

VALID

Processing of medical devices—Information to be provided by the medical device manufacturer

  • Issued on:2020-06-30
  • Implemented on:2021-12-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $340.00
$330.00
Standard No: YY/T 0802-2020
Document status: VALID
Title in English: Processing of medical devices—Information to be provided by the medical device manufacturer
Title in Chinese: 医疗器械的处理 医疗器械制造商提供的信息
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2020-06-30
Implemented on: 2021-12-01
Superseding: YY/T 0802-2010 Sterilization of medical devices—Information to be provided by the manufacturer for the processing of resterilizable medical devices
Chinese Classification: C47-Public medical equipment
Professional Classification: YY-Pharmaceutics
Related Keywords: medical device manufacturer
medical device manufacturer yy/t
medical device manufacturer bibliography
medical device
reusable medical device
Related Topics: Laboratory and Medical Devices
sample instrument manufacturer
peek medical device
Medical Device Laboratory
Medical Device Laboratory
Medical Device Aging Test
Medical device research
Principles of Medical Devices
Processing Equipment Manufacturers
head medical device
Medical Device Aging Test
Medical device research
Medical Device Central Laboratory
Medical Device Sales
Medical Device Rhythm Requirements
Medical Device Nickel
Major Instrument Manufacturers
over-the-counter devices
Medical Device Technology Development
Sales of medical devices
Spectrum Medical
Prescription Devices
medical device fda
medical device fda
Realize the quality of medical devices
Prescription Devices
40 years of medical
Overseas Data of Medical Devices
National Medical Devices
Frontier Technology of Medical Devices
Analyzer Medical Device
Validation of medical devices and
Medical Device Program
Class II medical machinery
Accelerated testing of medical devices
Correction of medical devices
List of medical devices
Medical device parameters
Medical device parameters
Medical devices include
Principles of Medical Devices
Medical Device Disposal Methods
Medical Device Annual Plan
Number of medical devices
Are Class II Medical Devices Safe?
Three types of medical device management system
gb in medical device
List of Class II Medical Devices
Medical device revision
Validation methods for medical devices
Medical Device Sales Regulations
Types of medical devices
Is the outer box required for medical devices?
Medical Device Confirmation
medical device manufacturer
How to sell medical devices
fda class one medical device
Medical Devices for Animals
Analysis Cup Medical Devices
Medical Device Effectiveness
Development and development of a class of medical devices
Research and development of a class of medical devices
Class I medical device technology
R&D of Class II medical devices
R&D of Class II Medical Devices
Large medical device manufacturers
How to import medical devices
Maintenance and maintenance of Class II medical devices
How to explain non-medical devices
Parameters of medical devices
Unqualified Medical Devices
Imported Class II Medical Devices
Class II medical device use management
Medical device outer box management
Medical device network batch
medical warmer
Medical Device Recycling
medical equipment wheel
yy/t0802
Medical Device Coding
Medical Collagen Manufacturer
Advanced Overseas Medical
medical spectrum
medical monitor
Frontier Technology of Medical Devices
Automatic Analysis of Medical Devices
Class II medical machinery
medical equipment
Non-medical device operation box
Medical Device Country
Class I medical device packaging
Flow Tube Medical Devices
YY/T 0802-2010
General Information for Medical Device Manufacturers
Medical device temperature
There are too many men in the medical device industry
Medical device hollow packaging
ivd medical device related
Medical model product manufacturing
Medical equipment noise
Medical device hazard assessment
Medical device methodology validation
Medical device environmental residue testing
Medical device laboratories follow
Medical device methodology validation
What to use for the aging of medical devices
Medical device packaging design
Methodology Validation of Medical Devices
Medical device eye fluid testing
Medical device test solution preparation
Class II medical device selection
yy/t 0802-2020
Medical device cooling holes
yy/t 0802


YY/T 0802-2020 Processing of medical devices - Information to be provided by the medical device manufacturer

1 Scope

This document specifies requirements for the information to be provided by the medical device manufacturer for the processing of a medical device that requires cleaning followed by disinfection and/or sterilization to ensure that the device is safe and effective for its intended use. This includes information for processing prior to use or reuse of the medical device.

Processing instructions are not defined in this document. Rather, this document specifies requirements to assist manufacturers of medical devices in providing detailed processing instructions that consist of the following activities, where applicable:

a) initial treatment at the point of use;

b) preparation before cleaning;

c) cleaning;

d) disinfection;

e) drying;

f) inspection and maintenance;

g) packaging;

h) sterilization;

i) storage;

j) transportation.

This standard are applicable to medical devices that are intended for invasive or other direct or indirect patient contact.

This standard excludes processing of the following:

——non-critical medical devices not intended for direct patient contact;

——textile devices used in patient draping systems or surgical clothing;

——medical devices specified by the manufacturer for single-use only and supplied ready for use.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

YY/T 0316 Medical devices - Application of risk management to medical devices (YY/T 0316-2016, ISO 14971: 2007, IDT)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1
cleaning
removal of contaminants to the extent necessary for further processing or for intended use

[GB/T 19971-2015, Definition 2.7]

Note: Cleaning is for the safe processing of medical devices and/or the next processing. Cleaning agents and water are often used to remove contaminants (such as blood, protein and other debris) attached to the surface, crevices, serrations, joints and lumen of medical devices by a manual or automated process.

3.2
disinfecting agent
physical or chemical agent that is able to reduce the number of viable microorganisms

3.3
disinfection
process to reduce the number of viable microorganisms to a level previously specified as being appropriate for a defined purpose

3.4
manual cleaning
removal of contaminants from an item to the extent necessary for further processing or for intended use without the use of an automated process

3.5
manufacturer
natural or legal person with responsibility for design and/or manufacture of a medical device with the intention of making the medical device available for use, under his name; whether or not such a medical device is designed and/or manufactured by that person himself or on his behalf by another person(s)

[YY/T 0287-2017, Definition 3.10]

Note: Attention is drawn to the fact that the provisions of national or regional regulations can apply to the definition of manufacturer.

3.6
packaging system
combination of the sterile barrier system and protective packaging

[GB/T 19971-2015, Definition 2.28]

3.7
processing
activity to prepare a new or used healthcare product for its intended use

Note: For the purposes of this document, processing includes cleaning, disinfection and/or sterilization.

3.8
processor
organization and/or individual with the responsibility for carrying out actions necessary to prepare a new or reusable healthcare product for its intended use

3.9
protective packaging
configuration of materials designed to prevent damage to the sterile barrier system and its contents from the time of their assembly until the point of use

[GB/T 19971-2015, Definition 2.37]

3.10
reusable medical device
medical device designated or intended by the manufacturer as suitable for processing and reuse

3.11
service life
number of processing cycles and/or life-time that a medical device can be subjected to and remain suitable and safe for its intended use

3.12
single-use medical device
medical device designated or intended by the manufacturer for one-time use only

Foreword i
Introduction iii
1 Scope
2 Normative references
3 Terms and definitions
4 Validation of the processes identified in the information
5 Risk analysis
6 Information to be provided by the medical device manufacturer
7 Presentation of the information
Annex A (Informative) Commonly used processing methods
Annex B (Informative) Example of processing instructions for reusable medical devices
Annex C (Informative) Classification of medical device
Annex D (Informative) Additional guidance on information to be provided by the medical device manufacturer
Bibliography

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend