Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
transfer sets alternative transfer set single use transfer sets 0804-2010 transfer sets alternative transfer water-supply well structure digital interface medical push-pull automatic doors
YY/T 0804-2010 in English

YY/T 0804-2010 in English

VALID

Transfer sets for pharmaceutical preparations―Requirements and test methods

  • Issued on:2010-12-27
  • Implemented on:2012-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $370.00
$359.00
Standard No: YY/T 0804-2010
Document status: VALID
Title in English: Transfer sets for pharmaceutical preparations―Requirements and test methods
Title in Chinese: 药液转移器 要求和试验方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2010-12-27
Implemented on: 2012-06-01
ICS Classification: 11.040.20-Transfusion, infusion and injection equipment
Chinese Classification: C31-General and microsurgical devices
Professional Classification: YY-Pharmaceutics
Related Keywords: transfer sets
alternative transfer set
single use transfer sets
0804-2010 transfer sets
alternative transfer
Related Topics: yy/t 0799-2010
yy/t 0797-2010
yy/t+0799-2010
yy/t0072-2010
yy/t1183-2010
gas phase transfer method
yy t 1183 2010
liquid transfer system
Pipette Sets
Liquid medicine equipment
Whose pipette
Electromechanical pipette
pipette method
yy/t 0806-2010
Pipette second gear
Pipette
Method transfer instrument
How to press the pipette
pipette so
Liquid phase method requirements
ich method transfer
Liquid Chromatography Method Validation Transfer
Pipette Calibration Method
Analytical Method Transfer Acceptance
Pipette acceptance
Micropipette test method
Liquid phase requirements for drug inspection standards
Commonly used pipette aspiration methods
What are the pipette calibration methods?
LC analysis method transfer
Method transfer is acceptable
Attention should be paid to the transfer of analytical methods
Method Validation Pharmacopoeia Liquid Quality
Method transfer between different liquid phase instruments
Liquid phase method converter
Analytical method validation pipettes
Pipette + Industry
Drug affinity test methods
Principles and methods of pipetting
Pharmacopoeia Analytical Method Validation Requirements
Liquid phase method transfer quantitation limit requirements
Two pipetting methods for pipette guns
Method transfer part verification
method transfer accept
Pharmacopeial method transfer
yy/t0813-2010
Transfer Conductance Test Method
Pipette Calibration Method
The difference between method transfer and method confirmation
yy/t 0804
yy/t 0693-2010


YY/T 0804-2010 Transfer sets for pharmaceutical preparations - Requirements and test methods

1 Scope

This standard is applicable to sterilized single use transfer sets that are used for pharmaceutical preparations.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 1962.1 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement (GB/T 1962.1-2001, ISO 594-1:1986, IDT)
GB/T 1962.2 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings (GB/T 1962.2-2001, ISO 594-2:1998, IDT)
GB 8368 Infusion sets for single use - Gravity feed (GB 8368-2005, ISO 8536-4: 2004, MOD)
GB 15811-2001 Sterile hypodermic needles for single use (eqv ISO 7864:1993)
YY/T 0466.1 Medical devices- Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements (YY 0466.1-2009, ISO 15223-1:2007, IDT)
ISO 8362 Injection container and its accessories
ISO 8536-2 Infusion equipment for medical use - Part 2: Closures for infusion bottles
ISO 15747:2003 Plastics containers for intravenous injection
ISO 15759:2005 Medical infusion equipment - Plastics caps with inserted elastomeric liner for containers manufactured by the blow-fill-seal (BFS) process

3 Design and designation

3.1 Design of transfer set without housing

The designs of the individual components are given in the drawings (Figures 1 to 4). The drawings serve as an illustration of possible designs of transfer sets. Other designs are acceptable.


a) Transfer set with one channel b) Transfer set with one channel, combined with a Luer taper
Figure 1 Transfer set with one channel


a) Transfer set with an air inlet/air outlet b) Alternative transfer set with an air inlet/air outlet

c) Transfer set with an air inlet, combined with a Luer taper

Figure 2 Transfer set with an air inlet

a) Transfer set with two channels b) Alternative transfer set with two channels
Figure 3 Transfer set with two channels

Key for Figures 1 to 3

1——piercing device;

2——channel;

3——channel with air filter for ventilation, optionally lockable;

4——protective cap;

5——connection of piercing devices by hub, grip plate or tube;

6——internal Luer taper.

3.2 Design of a transfer set with housing

The design of a transfer set with housing is given in Figure 4. The drawings serve as an illustration of possible types of transfer sets. Other designs are acceptable.

Foreword i
Introduction ii
1 Scope
2 Normative references
3 Design and designation
4 Material
5 Physical requirements
6 Chemical requirements
7 Biological requirements
8 Test method
9 Testing of chemical requirements
10 Testing of biological requirements
11 Packaging
12 Storage
13 Labelling
Annex A (Normative) Testing of fragmentation of transfer sets with plastic piercing devices
Annex B (Normative) Testing of fragmentation of transfer sets with metal piercing devices
Annex NA (Normative) Technical differences between this standard and ISO 22413:2007 and their justifications
Bibliography