Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
composite beam frame frame structure composite beams scopethis regulation frame structural systems confined rc columns steels introductionthis standard 629-2019 evaluation standard metamorphic
CECS 347-2013 in English

CECS 347-2013 in English

VALID

Technical Specification for Frame Structure of Confined RC Columns and Composite Beams

  • Issued on:2013-07-05
  • Implemented on:2013-09-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $750.00
$728.00
Standard No: CECS 347-2013
Document status: VALID
Title in English: Technical Specification for Frame Structure of Confined RC Columns and Composite Beams
Title in Chinese: 约束混凝土柱组合梁框架结构技术规程
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2013-07-05
Implemented on: 2013-09-01
Professional Classification: CECS-Engineering Construction Standard
Related Keywords: composite beam frame
frame structure
composite beams scopethis regulation
frame structural systems
confined rc columns
Related Topics: Column pressure ratio
soil column
constraint
column mixer
soil column
Trough mixer structure
Concrete-filled steel tube beam structure technology


Scope

This regulation is applicable to confined concrete column composite beam frame structures in non-seismic areas and seismic areas with seismic fortification intensity of 6 to 8 degrees. This regulation does not apply to special-shaped column frame structural systems.

Sample only — not a preview of CECS 347-2013
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend