Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
urban road lighting engineering urban road lighting urban road street lighting installation explanation low-voltage cabling engineering flaked glaze celadon similar healthful massage chair introduction key points special car lifts
CJJ 89-2001 in English

CJJ 89-2001 in English

SUPERSEDED

Specification for Construction and Inspection of Urban Road Lighting Engineering

  • Issued on:2001-07-30
  • Implemented on:2001-11-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $370.00
$359.00
Standard No: CJJ 89-2001
Document status: SUPERSEDED
Superseded by: CJJ 89-2012 Specification for construction and inspection of urban road lighting engineering
Superseded on: 2012-11-01
Title in English: Specification for Construction and Inspection of Urban Road Lighting Engineering
Title in Chinese: 城市道路照明工程施工及验收规程
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2001-07-30
Implemented on: 2001-11-01
Chinese Classification: P63-Power supply and distribution engineering
Professional Classification: CJ-Urban Construction
Related Keywords: urban road lighting engineering
urban road lighting
urban road
street lighting installation explanation
low-voltage cabling engineering
Related Topics: Gas tank project construction and acceptance
Municipal Engineering Laboratory
city road
Regulations for construction and acceptance of urban road lighting projects
Urban road engineering construction and quality inspection
Roofing construction and acceptance
urban road lighting
Construction and acceptance of electrical lighting installations
Distribution line inspection and construction
Construction and acceptance
Acceptance of engineering materials
Engineering construction and acceptance
Local communication line engineering and construction acceptance
Regulations for construction and acceptance of empty insulated distribution lines
cJJ2008-1 Urban Road Acceptance
Municipal railway electrification project construction and quality acceptance
The latest version of acceptance specifications for factory and mine road construction
Municipal electrification project construction and quality acceptance
Urban underground road engineering design
Chromatography acceptance process and
Factory and mine road construction acceptance
Directional drilling construction pipeline acceptance
Mechanical and electrical engineering toll lane acceptance


1.0.1 This specification is formulated within a view to adapting to the development of urban road lighting engineering, guaranteeing the construction quality of street lighting engineering, promoting technological progress and ensuring the safe and economical operation of lighting facilities
1.0.2 This specification is applicable to the installation of urban road lighting facilities at 10 kV or below as well as the construction and acceptance of overhead lines and low-voltage cabling engineering.
1.0.3 The apparatuses for urban road lighting as well as their transport and storage shall meet the relevant requirements of “Code for Construction and Acceptance of 35kV and Under Over-head Power Levels Electric Equipment Installation Engineering” (GB 50173); where the products have special requirements, it shall also meet the requirements of relevant technical documents.
1.0.4 The apparatus and equipment shall be checked in accordance with the following requirements:
1 The technical documents shall be complete.
2 The model, specification and appearance quality shall meet the design requirements and the requirements of this specification.
1.0.5 The construction and acceptance of urban road lighting engineering shall not only comply with this specification, but also meet the requirements of relevant national current compulsory standards.

Foreword I
1 General Provisions
2 Overhead Lines
3 Low-voltage Cable Lines
4 Transformer and Box-type Substation
5 Distribution Equipment and Control
6 Safety Protection
7 Street Lighting Installation
Explanation of Wording in This Specification

Sample only — not a preview of CJJ 89-2001
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.