CJ/T 250-2018 in English
VALIDHigh density polyethylene pipes and fittings for drainage inside buildings
- Issued on:2018-10-30
- Implemented on:2019-04-01
- File Format:PDF
- Delivery:Via email within 5 business days
$534.00
Introduction
Analysis of the key points of standard revision
| Revision content | 2007 edition | 2018 edition | Technical impact |
|---|---|---|---|
| Referenced standards | EN 1053/1054 | GB/T 5836.1 | Localization adaptation |
| Material requirements | PE100 is not specified | New PE100 performance indicators | Improve pressure bearing capacity |
| Testing items | 8 items | 4 new items such as impact resistance and welding strength | Strengthening quality control |
Key technical requirements
Material properties
The raw materials must be PE80 or PE100 mixed materials, with a carbon black content of (2.5±0.5)%, a melt flow rate of 0.2-1.1g/10min, and an oxidation induction time of ≥20min (200℃).
Pipe series selection
Siphon rainwater system must use S12.5 series pipes with "BD" markings, with a ring stiffness of ≥8kN/m² and a vacuum test pressure of -0.08MPa.
Implementation suggestions
- Pipes should be stored away from direct sunlight, and the stacking height should be ≤1.5m
- The working voltage of electric fusion pipe fittings is 220V±15V, and a special welding machine is required
- After the system is installed, temperature rise resistance cycle (1500 times) and water tightness test are required
Technology evolution analysis
This standard is not equivalent to ISO 8770:2003, and the main differences are: the connection method focuses on butt welding/electric fusion (socket joints are limited to expansion joints), the application scope is extended to siphon rainwater systems, and the PE100 material grade requirement is added.