DB/T 83-2020 in English
VALIDActive fault survey-Inspection of database
- Issued on:2020-03-30
- Implemented on:2020-07-01
- File Format:PDF
- Delivery:Via email within 5 business days
$301.00
本标准规定了活动断层数据库检测的内容、方法、流程以及检测结果记录与评定。
本标准适用于活动断层填图、城市活动断层探测以及断层活动性鉴定等数据库的检测。
Introduction
Analysis of the core content of the standard
| Detection dimensions | Quantitative elements | Qualitative elements | Detection methods |
|---|---|---|---|
| Data integrity | Amount of redundant/missing data | Data timeliness | Computer automatic detection |
| Logical consistency | Value range/topology rules | Processing flow | Template comparison + manual review |
| Spatial accuracy | Coordinate error ≤19 tolerance | Map consistency | Layer overlay detection |
Key technical points
Fault strike consistency detection requires that the deviation between the geometric trend and the attribute field dip be controlled within the 15° range. For example: when the fault line strikes N45°E, the dip attribute value should be between N30°E and N60°E.
Computer automatic detection is achieved through the spatial azimuth calculation algorithm, and manual detection needs to be verified with the geological compass measurement data.
Background of Standard Evolution
This standard inherits the ISO 19157:2013 data quality framework, and adds the following features for active fault data:
- Fault-specific topological rules (Appendix A.7)
- 17-digit ID coding verification mechanism (6-digit city code + 3-digit thematic code + 8-digit custom code)
- Field sampling accuracy and spatial matching requirements for total station measurement data
Implementation Suggestions
- Establish a detection rule library: Develop an automated verification script based on Appendix A
- Phase-by-stage quality control: Embed detection nodes in each link of data collection, storage and update
- Use the spatial analysis module of the GIS platform for topological verification
- The detection report should include the 8 core contents specified in Clause 11.2

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

DB/T 68-2017 in English
Integrated lightning protection of seismic stations
2017-09-26 -

DB51/T 988-2010 in English
2010-02-10 -

DB22/ 398-2005 in English
2005-04-01 -

DB43/T 3292-2025 in English
2025-07-18 -

DB61/T 1775-2023 in English
2023-12-22 -

DB23/T 3845-2024 in English
2024-08-30 -

DB11/T 1044-2013 in English
2013-12-20 -

DB37/T 4185-2020 in English
2020-11-10 -

DB11/T 2028-2022 in English
2022-09-29 -

DB32/T 5218-2025 in English
2025-10-30