Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
supply configuration specification power supply configuration requirements main transformer power supplies external power supply emergency power supply designing ac station service other organochlorine pesticide residues γ-ray density inspection vehicle
DL/T 5155-2016 in English

DL/T 5155-2016 in English

VALID

Technical Code for Designing AC Station Service of 220kV~1000kV Substation

  • Issued on:-
  • Implemented on:-
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $680.00
$660.00

本标准适用于新建、扩建和改建的220kV-1000kV变电站、开关站、串补站的交流站用电系统设计。


Introduction

Core changes in the standard revision

Dimensions 2002 Edition 2016 Edition
Voltage Range 220kV~500kV Expanded to 1000kV
Chapter Structure 8 Chapters 10 Chapters (New chapters on terminology and electric shock protection)
Emergency Power Supply Not clear New requirements for self-provided power supply

Analysis of key technical points

1. Power supply configuration specification

Power supply configuration requirements for substations of different voltage levels:

  • 220kV station: at least 2 main transformer low-voltage side power supplies + 1 external power supply
  • 1000kV station: 2 main transformer power supplies + 2 external power supplies from different sources

2. Load classification management

Load type Impact of power outage Typical equipment
Class I Direct impact on safety Main transformer cooling system
Class II Affect normal operation Lighting system

Implementation suggestions

Key points for transformer selection

  1. Give priority to the connection group Dyn11
  2. The capacity must meet the calculation formula S≥0.85P1+P2+P3
  3. When the voltage fluctuation is >5%, an on-load tap-changing transformer should be used

Short-circuit protection design

The short-circuit current calculation of the low-voltage system needs to consider:

  • Power supply conditions of a single transformer
  • Influence of feeder impedance
  • For the specific algorithm of the 380V system, see Appendix C

Sample only — not a preview of DL/T 5155-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • DL 5073-1997 in English

    DL 5073-1997 in English

    Code for seismic design of hydraulic structures

    1997-08-04
  • DL/T 790.12-2001 in English

    DL/T 790.12-2001 in English

    Distribution Automation Using Distribution Line Carrier Part 1: General Provisions Part 2: Guidelines for Formulation of Specifications

    2001-12-26
  • DL/T 790.11-2001 in English

    DL/T 790.11-2001 in English

    Distribution Automation Using Distribution Line Carriers Part 1: General Part 1: Architecture of Distribution Automation Systems

    2001-12-26