本标准规定了水工建筑物抗冲磨防空蚀(以下简称抗磨蚀)混凝土工程的设计、施工、维修和运行的原则。
本标准适用于水流流速小于40m/s的大、中型水利水电工程1、2、3级泄水建筑物的设计和施工,4、5级泄水建筑物设计和施工可参照执行。对于流速大于等于40m/s的泄水建筑物的抗磨蚀问题,应做专门研究