Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
secondary system design electrical secondary system protection system monitoring system system sensors trial run building decoration cotton spider
DL/T 5499-2015 in English

DL/T 5499-2015 in English

VALID

Technical Code for Design of Electrical Secondary System of Converter Station

  • Issued on:2015-04-02
  • Implemented on:2015-09-01
  • File Format:PDF
  • Delivery:Via email within 10 business days
Price(USD): $1,200.00
$1,164.00
Standard No: DL/T 5499-2015
Document status: VALID
Title in English: Technical Code for Design of Electrical Secondary System of Converter Station
Title in Chinese: 换流站二次系统设计技术规程
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 10 business days
Issued on: 2015-04-02
Implemented on: 2015-09-01
Professional Classification: DL-Electricity
Related Keywords: secondary system design
electrical secondary system
protection system
monitoring system
system sensors
Related Topics: Secondary range
secondary carrier
double reheat technology
secondary fluorescence technology
secondary shunt technology
Polarized secondary target technology
Second technology demonstration
dl/t422-2015
Secondary statistical instrument
Secondary reheat technology
DL/T 5499-2015
The whole process of SIS system design
secondary


Introduction

Standard Overview

DL/T 5499-2015 was approved and issued by the National Energy Administration. It standardizes the secondary system design of converter stations with voltage levels of ±800kV and below, including 13 chapters of technical content such as monitoring system and DC control protection.


Core Design Principles

System TypeConfiguration RequirementsTypical Equipment
Monitoring SystemDualized Network StructureServer, Workstation, I/O Unit
DC ProtectionTriple Measurement CircuitPhotoelectric Current Measurement Device
Valve Cooling SystemThree-out-of-two Tripping LogicTemperature/Flow Sensor

Technical Innovation Points

UHV DC layered protection: It adopts a three-level protection architecture of valve group layer (12-pulsation valve group), pole layer and bipolar layer. The sensitivity of the valve group-connected bus differential protection is increased by 40%

Typical application: Jinsu ±800kV project realizes bipolar power dynamic balance through valve group coordination control function


Implementation suggestions

  1. The control and protection system should pass the electromagnetic compatibility test (in compliance with DL/T 1087)
  2. The valve cooling system sensors are configured with redundant channels according to the two out of three principle
  3. Special trough boxes are used for optical cable laying, and they are arranged in layers with non-power cables

Sample only — not a preview of DL/T 5499-2015
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • DL/T 790.12-2001 in English

    DL/T 790.12-2001 in English

    Distribution Automation Using Distribution Line Carrier Part 1: General Provisions Part 2: Guidelines for Formulation of Specifications

    2001-12-26