Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
standard explosion-proof transparent materials anti-explosion transparent materials introduction analysis key parameters test method non-contact explosion grade key test equipment requirements dynamic pressure sensor contact explosion level photovoltaic grid-connected inverter equipment pvc floor sheets disease susceptibility dna
GA 667-2020 in English

GA 667-2020 in English

VALID

Anti-explosion transparent materials

  • Issued on:2020-01-19
  • Implemented on:2020-08-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $210.00
$204.00
Standard No: GA 667-2020
Document status: VALID
Title in English: Anti-explosion transparent materials
Title in Chinese: 防爆炸透明材料
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2020-01-19
Implemented on: 2020-08-01
Superseding: GA 667-2006 Blast resistant composited glass
ICS Classification: 13.310-Protection against crime
Chinese Classification: A90-Social and public safety in general
Professional Classification: GA-Security
Related Keywords: standard explosion-proof transparent materials
anti-explosion transparent materials introduction analysis
key parameters test method non-contact explosion grade
key test equipment requirements dynamic pressure sensor
contact explosion level
Related Topics: transparent material
explode
Combined Explosion
net explosive quantity
Explosion-proof
Bromine becomes transparent
What is the transparency of the material?
western oil explosion
Material transmission sample preparation
Transparency of various materials
Material light transparent window
Beihua Explosion
transparent film material
burst
transparent transparency
chemical park explosion
explosion chemical explosion
Sanning Explosion
Transparent material phase
transparent metal material
various transparent materials
what material transparency
How transparent is the material
Exploding Nuts
through
recent explosion
explosion measure
Anti-knock material
transparent electrode
pe material transparency
Transparent waterproof glue transmittance
Oral material transparency
Transparency Grading of Oral Materials
Explosion hole test
Explosion-proof breathable sheet

本标准规定了防爆炸透明材料的分类、分级和代号、技术要求、试验方法、检验规则、包装、运输和贮存,适用于具有防爆炸性能需求的防爆炸复合玻璃等透明板材的生产、检验和验收。


Introduction

Analysis of the core content of the standard

Explosion-proof transparent materials: refers to panels such as composite glass with a light transmittance ≥55% and that can withstand specific explosion impacts. They are divided into Class A (cracks/splashes on the back) and Class B (no cracks and no splashes) according to their protection capabilities.

Comparison of key technical indicators

Performance type Grading Key parameters Test method
Non-contact explosion Grade 1-7 Shock wave overpressure peak value 110-1000kPa Appendix A Dynamic Pressure Test
Proportional distance=explosion distance/(TNT equivalent1/3)
Contact explosion Level 1-3 TNT charge 50-150g Hemispherical explosive surface detonation

Key points of standard evolution

2006 version → New version major changes:
  • Added 6 new terms (blast center, proportional distance, etc.)
  • Refined explosion-proof performance classification (non-contact 7 levels → original 5 levels)
  • Added Dimensional deviation requirements (thickness 11-100mm tolerance ±0.5-5mm)
  • Modify the transmittance index (non-contact level 7 requires ≥55%)

Implementation and application suggestions

Product selection example

Financial venues recommend the use of FBC-D5B/V2A-30:
- Non-contact level 5 (570kPa shock wave)
- Contact level 2 (100g TNT)
- Class B back protection
- 30mm nominal thickness

Key points for quality control

  1. Each batch must be tested for transmittance (GB 5137.2 optical test)
  2. Explosion-proof performance sampling according to GB/T 2829 periodic inspection
  3. Packaging must contain impact surface marking

Key test equipment requirements

Dynamic pressure sensor:
- Linear error ≤1%
- Rise time ≤4μs
- Sampling rate ≥1MSa/s (data acquisition system)
Note: GJB 338A explosive equivalent calibration is required regularly

Sample only — not a preview of GA 667-2020
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend