GB/T 11297.11-2015 in English
VALIDTest method for dielectric constant of pyroelectric materials
- Issued on:2015-12-31
- Implemented on:2016-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$88.00
Introduction
GBT11297.11-2015 Standard Overview
GB/T11297.11-2015 "Test Method for Dielectric Constant of Pyroelectric Materials" replaces the previous GB/T11297.11-1989. The main updates include applicable frequency range, test atmospheric conditions, sample size and requirements, etc.
Standard Development Background
Pyroelectric materials are widely used in electronics, communications and other fields. With the advancement of technology, there is an urgent need to improve material performance. This standard revision aims to meet the testing needs of new materials and optimize test accuracy and operation procedures.
| Old version requirements | New version requirements | Improvements |
|---|---|---|
| Frequency range: 100Hz~1MHz | Frequency range: 100Hz~100kHz | Adjust the applicable scope to focus more on mid- and low-frequency characteristics |
| Atmospheric conditions are not clear | Temperature: 15℃~35℃ Relative humidity: 25%~75% | Add arbitration test conditions to ensure consistency of results |
| Specimen size: not clear | Area: 10mm²~50mm² Thickness: 0.1mm~1.0mm | Refine the requirements and improve the test accuracy |
Term explanation and practical application
Pyroelectric material: refers to a material with pyroelectric effect, whose dielectric constant changes with temperature. For example: Lead titanate, Lead zirconate titanate, etc.
LCR meter: is used to measure inductance (L), capacitance (C) and resistance (R), and is the key equipment used to test dielectric constant in this standard.
Implementation suggestions
- Sample preparation: Ensure that the sample size and surface flatness meet the requirements. It is recommended to use a micrometer to measure the thickness.
- Test environment control: Maintain constant temperature (25℃±2℃) and relative humidity at 25%~75% to ensure data accuracy.
- Instrument calibration: Regularly calibrate the LCR meter, especially the capacitance measurement accuracy requirement to reach ±0.05%.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 16822-1997 in English
Test method for dielectric properties of dielectric crystal
1997-05-28 -

GB/T 37255-2018 in English
Test method for pyroelectric coefficient of materials under DC bias field
2018-12-28 -

GB/T 11297.10-2015 in English
Test method for curie temperature of pyroelectric materials
2015-12-31