GB/T 12919-2017 in English
VALIDSpecification for cleaning equipments of air source in ship
- Issued on:2017-07-31
- Implemented on:2018-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
《GB/T 12919-2017船用控制气源净化装置技术条件》由TC137(全国船用机械标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
National Standard of the People's Republic of China GB/T 12919-2017 replaces GB/T 12919-1991
Interpretation of Technical Requirements for Marine Control Air Source Purification Devices
Analysis of Standard Formulation Background and Technology Evolution
GB/T 12919-2017 is a comprehensive revision of GB/T 12919-1991, mainly targeting the technical requirements for marine control air source purification devices. The main changes in this revision include:
- Modified the name of the standard
- Expanded the rated processing flow range
- Increased the pressure dew point requirement
- Added new chapters on design and structure, appearance quality, etc.
- Optimized performance indicators and test methods
| Parameter dimension | Refrigeration purification device | Adsorption purification device |
|---|---|---|
| Rated processing flow | 0.3, 0.6, 1, 3, 6, 10, 20, 40, 60, 80, 100, 160, 200, 300 m³/min | 0.3、0.6、1、3、6、10、20、4060、80、100、160、200、300 m³/min |
| Inlet pressure | 0.16、0.7(0.8)、1、3.15 MPa | 0.16、0.7(0.8)、1、3.15 MPa |
| Inlet temperature | ≤40 ℃ | ≤40 ℃ |
| Pressure dew point | ≤10 ℃ | ≤120 ℃ |
Classification and working principle of purification device
Marine control air source purification device is mainly divided into two categories:
- Refrigeration type purification device: Use refrigeration equipment to cool compressed air, precipitate water, and then remove impurities through precision filters.
- Adsorption type purification device: Adsorbent is used to absorb water in compressed air, and then impurities are removed through precision filters.
Performance requirements and test methods
According to the standard requirements, the purification device must meet the following performance indicators:
- Dew point requirements: The atmospheric pressure dew point of the treated air should not be higher than -40 ℃.
- Pressure drop: Refrigeration type ≤5%, adsorption type ≤3%.
- Solid particle level: Reach level 1 as specified in GB/T13277.1-2008.
Implementation suggestions and application cases
In actual applications, it is recommended that users choose the appropriate type of purification device according to specific needs. For example:
- For high temperature environments, designs with cooling treatment are preferred.
- For scenarios that require frequent maintenance, adsorption purification devices can be considered.