GB/T 12966-2022 in English
VALIDThe methods for determining aluminium and aluminium alloys conductivity using eddy current
- Issued on:2022-03-09
- Implemented on:2022-10-01
- File Format:PDF
- Delivery:Via email within 5 business days
Price(USD):
$460.00
$447.00
$447.00
《GB/T 12966-2022铝及铝合金电导率涡流测试方法》由TC243(全国有色金属标准化技术委员会)归口,TC243SC1(全国有色金属标准化技术委员会轻金属分会)执行,主管部门为中国有色金属工业协会。
Introduction
Core changes in the standard revision
| Revision content | 2008 edition | 2022 edition |
|---|---|---|
| Test scope | Limited to aluminum alloy | Extended to aluminum and aluminum alloy |
| Definition of terms | 12 terms | Simplified to core terms such as measurement accuracy |
| Equipment requirements | No clear stability requirements | Added 30-minute stability indicator (±0.2MS/m) |
Key technical requirements
Test equipment specifications
Standard requirements for eddy current conductivity meters:
- Frequency range50kHz-500kHz (60kHz recommended)
- Test accuracy±0.2MS/m
- Lift-off suppression≤0.2MS/m
Typical equipment: SitestD2.069, SiscopeSMP350 conductivity meters
Comparison of test methods
| Project | Contact | Non-contact |
|---|---|---|
| Applicable scenarios | Precise measurement in the laboratory | Quick detection on the production line |
| Test accuracy | ±0.2MS/m | ±0.3MS/m |
| Special requirements | Surface cleaning required | Motion control device required |
Implementation suggestions
- Periodically check the equipment (every 6 months for contact type and every 3 months for non-contact type)
- For curved surface testing, the correction coefficient table provided in Appendix D is preferred
- For thin plate testing, it is recommended to use a 480kHz high-frequency probe