Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
high-voltage alternating-current fuse part high-voltage fuses high-voltage fuse-links standard formulation high-voltage ac fuses motor circuit introduction gb/t15166.5-2022 standard overview marine sediment measurement items drug residues frozen shrimp processing
GB/T 15166.5-2022 in English

GB/T 15166.5-2022 in English

VALID

High-voltage alternating-current fuse—Part 5:Application directives for high-voltage fuse-links for motor circuit

  • Issued on:2022-12-30
  • Implemented on:2023-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $130.00
$127.00
Standard No: GB/T 15166.5-2022
Document status: VALID
Title in English: High-voltage alternating-current fuse—Part 5:Application directives for high-voltage fuse-links for motor circuit
Title in Chinese: 高压交流熔断器 第5部分:用于电动机回路的高压熔断器的熔断件选用导则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-12-30
Implemented on: 2023-07-01
Superseding: GB/T 15166.5-2008 High-voltage Alternating-current Fuses – Part 5: Specification for High-voltage Fuse-links for Motor Circuit Applications
ICS Classification: 29.120.50-Fuses and other overcurrent protection devices
Chinese Classification: K43-High voltage switchgear
Professional Classification: GB-National Standard
Related Keywords: high-voltage alternating-current fuse part
high-voltage fuses
high-voltage fuse-links
standard formulation high-voltage ac fuses
motor circuit introduction gb/t15166.5-2022 standard overview
Related Topics: iec fuse
iec fuse
High voltage fuse
Fuse Standard
fuse
High voltage fuse
iec62271-100 high voltage circuit breaker
Purpose of the guideline
battery car fuse
battery car fuse
GB/T 15166.5
GB/T 15166.5-2008
High voltage AC circuit breaker and its components
Causes of blown transformer high voltage fuse
Current circuit of low voltage electroscope
How to choose fuse current
Encyclopedia of High Segmentation Capacity High Voltage Fuses
Selection of fuse rated current
AC high voltage circuit breaker new
High voltage circuit breaker selection
High frequency melt sample national standard
Generator melt circuit test

《GB/T 15166.5-2022高压交流熔断器 第5部分:用于电动机回路的高压熔断器的熔断件选用导则》由TC340(全国熔断器标准化技术委员会)归口,TC340SC1(全国熔断器标准化技术委员会高压熔断器分会)执行,主管部门为中国电器工业协会。


Introduction

GB/T15166.5-2022 Standard Overview

This standard specifies the technical requirements, type tests and information provided to users for high-voltage fuses used in motor circuits. It is applicable to fuses used for direct-start motors in 3kV and above, 50Hz AC systems.

Background of Standard Formulation

High-voltage AC fuses are widely used in power systems and factories and mines to protect lines and equipment. With the development of power grids and technological advances, the original standard GB/T15166.5-2008 can no longer meet current needs, so the standard has been revised.

Technical requirements

Technical requirements dimensions Specific requirements Scope of application
Fuse time-current characteristics For fuses with rated current Ir≤100A, If10/Ir≥3; for fuses with Ir>100A, If10/Ir≥4. All rated current values
K factor determines overload characteristics Select the K value when the pre-arcing time is 10s. The fuse should withstand repeated overloads under different starting conditions without damage. Applicable to frequent starting and abnormal operating conditions
Withstand requirements Fuse links should withstand rapid and continuous starting pulses without degradation, and withstand the motor starting current multiple times under normal operating conditions. Abnormal operating conditions and normal operating conditions

Standard implementation recommendations

When selecting fuse links, select the appropriate K value based on the starting frequency and operating conditions of the motor, and ensure that it meets the manufacturer's technical specifications. It is recommended to regularly inspect and maintain fuses to ensure their long-term effectiveness and reliability.

Sample only — not a preview of GB/T 15166.5-2022
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend