《GB/T 15187-2017湿式除尘器性能测定方法》由TC275(全国环保产业标准化技术委员会)归口,主管部门为国家发展和改革委员会。
Introduction
Analysis of the core content of the standard
GB/T 15187-2017, as the national standard for the performance measurement of wet dust collectors, systematically regulates the test method system for wet dust collectors. Compared with the 2005 version, the main technical evolution is reflected in:
| Technical Dimensions | 2005 Version | 2017 Version Improvements |
|---|---|---|
| Terminology | 3 definitions | New 3.3-3.7 Gas Humidity Related Terms |
| Determination Method | Single Point Sampling | Strengthen Gridded Multi-Point Sampling Requirements |
| Safety Specifications | Not Clear | New Flammable and Explosive Gas Protection Clauses |
| Reporting Requirements | Not an Independent Chapter | New Chapter 8 Report Writing Specifications |
Detailed explanation of key measurement technologies
1. Sampling system construction
The standard requires the establishment of a three-level quality control system:
- Measurement point arrangement: The circular flue adopts the equal area integral ring method. When the diameter is greater than 4m, 10-20 measurement points need to be arranged
- Instrument selection: Pitot tube coefficient error ≤2%, temperature measurement accuracy ≥ Level 1
- Working condition control: The dust concentration needs to be stable in the range of 1-20g/m³ during the test
2. Core parameter measurement
Dust removal efficiency measurement case: The test of a spray tower in a power plant shows that when the inlet concentration is 15.6g/m³:
- Isokinetic sampling flow rate: 28.5L/min (d=8mm)
- Filter cartridge weight gain: 4.2mg (quartz filter cartridge)
- Final efficiency: η=(15.6-0.3)/15.6×100%=98.1%
Implementation suggestions
1. On-site operation specifications
Note when performing dust concentration measurement:
- The sampling gun heating temperature needs to be controlled at 160±5℃
- The constant weight of the filter cartridge requires the difference between two weighings to be ≤0.3mg
- The SO2 absorption liquid needs to be kept in an ice bath at ≤25℃
2. Data quality control
| Parameter | Tolerance range | Calibration cycle |
|---|---|---|
| Dynamic pressure measurement | ±5Pa | 3 measurements per batch |
| Humidity measurement | ±3%RH | Sensor replacement every 2 years |
| Flow measurement | ±1%FS | Calibration in half a year |
3. Special working conditions processing
For high humidity flue gas (moisture content>15%vol):
- Condensation method is preferred for humidity measurement
- The sampling system needs to add an insulation sleeve
- Gas density needs to be corrected during calculation (Formula 13)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 33017.6-2024 in English
Technical requirements of high efficiency air pollution control equipment for assessment—Part 6: Wet electrostatic precipitator
2024-08-23 -

GB/T 33758-2017 in English
Disk tubular membrane equipment
2017-05-12 -

GB/T 33017.5-2017 in English
Technical requirements of high efficiency air pollution control equipment for assessment―Part 5:Air cleaners
2017-12-29