VALIDMechanical coupler for measurements on bone vibrators
- Issued on:1995-01-02
- Implemented on:1996-08-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
| Standard No: | GB/T 15951-1995 |
| Document status: | VALID |
| Title in English: | Mechanical coupler for measurements on bone vibrators |
| Title in Chinese: | 骨振器测量用力耦合器 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 1995-01-02 |
| Implemented on: | 1996-08-01 |
| ICS Classification: | 17.160-Vibrations, shock and vibration measurements |
| Chinese Classification: | A59-Acoustic Measurement |
| Professional Classification: | GB-National Standard |
| Related Keywords: | bone vibrators
bone vibrators scopethis standard bone conduction vibrator bone conduction hearing aids bone conduction audiometry |
| Related Topics: | standard coupler
bone coupler Bone vibrator measurement force coupler bone vibrator coupler GB 15951 GB/T 15951 gb+15951 bone mass Coupling test box Lihe Vibration + vibration GBT15951 Magnetic coupler vibration failure |
《GB/T 15951-1995骨振器测量用力耦合器》由TC23(全国电声学标准化技术委员会)归口,主管部门为工业和信息化部(电子)。
本标准规定了力耦合器的要求。本标准用于听力测定。力耦合器也可用于听力计骨振器的频率响应、不需要的声辐射、谐波失真及其他测量。
Scope
This standard specifies the requirements for force couplings. The force coupler is used in the frequency range of 125Hz to 8000Hz for calibrating bone conduction audiometers, measuring bone vibrators (bone conduction earphones) and measuring bone conduction hearing aids. This standard is used for audiometry, and its purpose is to provide a calibration method for bone vibrators used in bone conduction audiometry by specifying the standard force impedance loaded on the vibrator and the device for measuring the alternating force generated. GB 11669 specifies the corresponding The reference equivalent hearing threshold level of normal hearing threshold. For this reason, according to the regulations in GB 7341, the bone conduction vibrator requires a flat dome with an area of 175±mm2, and a static force of 5.5N±0.5N acts on the force coupler. The force coupler It can also be used for frequency response of audiometer bone vibrator, unwanted sound radiation, harmonic distortion and other measurements. The purpose of this standard for drawing hearing aids is to measure the electromechanical characteristics (sensitivity, frequency response, harmonic distortion, etc.) of bone vibrators used in hearing aids; When the static force in the range of 1.7N ~ 4N is added, the sound-force characteristic of the whole bone conduction hearing aid is measured.