GB/T 16803-2018 in English
VALIDEquipment of heating,ventilating,air conditioning and air cleaning terminology
- Issued on:2018-05-14
- Implemented on:2019-04-01
- File Format:PDF
- Delivery:Via email within 5 business days
$728.00
《GB/T 16803-2018供暖、通风、空调、净化设备术语》由TC143(全国暖通空调及净化设备标准化技术委员会)归口,主管部门为住房和城乡建设部。
Introduction
Standard Evolution and Framework Analysis
| Comparison Dimensions | GB/T 16803-1997 | GB/T 16803-2018 |
|---|---|---|
| Total Number of Terms | 328 items | 512 items (an increase of 56%) |
| New Chapters | 4 Major Modules | 6 new technical sections including Household Heat Sources and Heat Metering Devices |
| Technology Update | Mainly traditional equipment | Added 21 new technical terms such as capillary radiation and solution humidification |
Core Equipment Terminology Essentials
1. Heating Equipment
Metal Thermal Strength (2.1.5): A key indicator for quantifying the energy efficiency of radiators, in W/(kg·K). The higher the value, the higher the heat dissipation efficiency of the unit metal material. The value of the new copper-aluminum composite radiator can reach 1.2-1.5, which is 40% higher than that of the traditional cast iron radiator.
2. Ventilation equipment
Venturi valve (3.3.15): A precision air volume control device based on the principle of fluid mechanics, with a control accuracy of ±5%, widely used in laboratory variable air volume systems. Compared with ordinary air valves, it saves 15%-30% energy.
3. Air purification
ULPA filter (5.2.9): The filtration efficiency of 0.3μm particles is ≥99.999%, mainly used in chip manufacturing, biosafety laboratories and other scenarios. It needs to be used with the fan filter unit (5.4.8).
Implementation recommendations
- Design phase: Strictly distinguish between the selection and calculation of radiant heating devices (2.2.2) and conventional convection heating equipment
- Purchase and acceptance: Verify the air filter efficiency mark against Chapter 5 of the standard to avoid confusing weight efficiency with counting efficiency
- Operation and maintenance management: Regularly check the accuracy of the paired temperature sensors of the heat meter (2.5.1). Calibration is required if the error exceeds 0.1℃
Typical application cases
The operating room of a tertiary hospital adopts the biological clean room (5.3.5) design and uses in combination:
- High and medium efficiency filters (5.2.6) as pre-filters
- High-efficiency air outlets (5.4.3) achieve vertical unidirectional flow
- Air volume control uses pressure-independent VAV terminals (4.6.3.7)
The measured cleanliness reaches ISO Class 5 standard, and annual energy consumption is reduced by 22%.