Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
valve device stacks terminal markings valve device units power convertor equipment scopethis standard terminal marking system container freight handover methods element carbon hydrogen indoor-outdoor optical fibre cables
GB/T 16859-1997 in English

GB/T 16859-1997 in English

VALID

Terminal markings for valve device stacks and assemblies and for power convertor equipment

  • Issued on:1997-09-01
  • Implemented on:1998-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $150.00
$146.00
Standard No: GB/T 16859-1997
Document status: VALID
Title in English: Terminal markings for valve device stacks and assemblies and for power convertor equipment
Title in Chinese: 阀器件堆、装置和电力变流设备的端子标记
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 1997-09-01
Implemented on: 1998-03-01
ICS Classification: 29.200-Rectifiers. Convertors. Stabilized power supply
Chinese Classification: K46-Power semiconductor device and parts
Professional Classification: GB-National Standard
Related Keywords: valve device stacks
terminal markings
valve device units
power convertor equipment scopethis standard
terminal marking system
Related Topics: flow secondary antibody labeling
GB/T 16859
gb/t+16859
gb/t16859
gb16859
gb 16859
flow secondary antibody labeling
flow secondary antibody labeling
GBT16859

《GB/T 16859-1997阀器件堆、装置和电力变流设备的端子标记》由TC60(全国电力电子系统和设备标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准适用于阀器件堆、装置及由工厂组装的整体变流设备的主电路的端子标记。端子标记是针对由半导体阀器件构成的堆、装置及设备的。


Scope

This standard is applicable to the terminal markings of valve device stacks, devices and the main circuit of the overall inverter equipment assembled by the factory. The terminal markings are aimed at stacks, devices and equipment composed of semiconductor valve devices. Note: This standard does not consider the auxiliary circuit including the gate terminal, the non-integral assembly of the converter equipment, its parts are manufactured separately, and the connection between them is only carried out at the time of field installation. For such equipment the relevant standards for the individual components apply. The purpose of this standard is to specify a logical alphanumeric marking system for the marking of main circuit external terminals in stacks, valve device units or integrally assembled solid-state converter equipment. The marking system is suitable for circuit diagrams, product catalogs, instructions and exchanged and archived materials. The marking method adopted is based on IEC145. In the case of stacks and installations, an alphanumeric marking system is used to mark those variable flow connections considered in IEC 971, and those connections which are the most important and frequently used, also for the marking line given in the example in Clause 5. made with identifiers from the same publication. This standard does not include a terminal marking system identified by graphic symbols and colors. Note: The marking of the terminals of the auxiliary circuit should be clearly identifiable.

Sample only — not a preview of GB/T 16859-1997
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 36956-2018 in English

    GB/T 36956-2018 in English

    Testing of voltage sourced converter valve base control unit for high-voltage direct current power transmission using voltage sourced converters

    2018-12-28
  • GB/T 44802-2024 in English

    GB/T 44802-2024 in English

    Technical specification for insulated-gate bipolar transistor (IGBT) driver of high-voltage direct current power transmission using voltage sourced converters

    2024-10-26
  • GB/T 17950-2000 in English

    GB/T 17950-2000 in English

    Semiconductor converter - Part 6: Application guide for the protection of semiconductor converters against overcurrent by fuses

    2000-01-03
  • GB/Z 29630-2013 in English

    GB/Z 29630-2013 in English

    Static var compensators(SVC)—System design and application guidelines

    2013-07-19
  • GB/T 29629-2013 in English

    GB/T 29629-2013 in English

    Water cooling equipment for static var compensators

    2013-07-19
  • GB/Z 163.4-2025 in English

    GB/Z 163.4-2025 in English

    High-voltage direct current (HVDC) systems—Guidance to the specification and design evaluation of AC filters—Part4:Equipment

    2025-12-03
  • GB/T 13422-2013 in English

    GB/T 13422-2013 in English

    Semiconductor converters—Electrical test methods

    2013-07-19
  • GB/T 33595-2017 in English

    GB/T 33595-2017 in English

    Motor soft-start device--Method of type designation

    2017-07-12