Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
electrical equipment measuring equipment terminals low voltage distribution systems output voltage un voltage output low voltage distribution fluid-viscous clutches blend r507 series introductionthis idesia polycarpa maxim
GB/T 18216.2-2012 in English

GB/T 18216.2-2012 in English

SUPERSEDED

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance

  • Issued on:2012-11-05
  • Implemented on:2013-02-15
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $120.00
$117.00
Standard No: GB/T 18216.2-2012
Document status: SUPERSEDED
Superseded by: GB/T 18216.2-2021 Electrical safety in low voltage distribution systems up to 1 000 V a. c. and 1 500 V d. c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
Superseded on: 2021-12-01
Title in English: Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
Title in Chinese: 交流1000V和直流1500V以下低压配电系统电气安全 防护措施的试验、测量或监控设备 第2部分:绝缘电阻
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2012-11-05
Implemented on: 2013-02-15
Superseding: GB/T 18216.2-2002 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measuring - Part 2: Insulati
Chinese Classification: N20-Electrical instrument and meter in general
Professional Classification: GB-National Standard
Related Keywords: electrical equipment
measuring equipment terminals
low voltage distribution systems
output voltage un voltage output
low voltage distribution
Related Topics: GB/T18216.2-2002
Safety precautions
Devices for Monitoring Current
GB/T 18216.2
GB/T 18216.2-2002
GB/T 18216.2-2012
GB/T 18216.2-2021
Testing, measuring or monitoring equipment for electrical safety protection measures in low-voltage power distribution systems
Electrical safety AC and DC withstand voltage insulation tester
Monitoring equipment insulation resistance test

《GB/T 18216.2-2012交流1000V和直流1500V以下低压配电系统电气安全 防护措施的试验、测量或监控设备 第2部分:绝缘电阻》由TC104(全国电工仪器仪表标准化技术委员会)归口,TC104SC2(全国电工仪器仪表标准化技术委员会电工和电磁量测量设备分会)执行,主管部门为中国机械工业联合会。


1 Scope

This part of GB/T 18216 specifies the requirements applicable to equipment for measuring the insulation resistance of equipment and installations in the de-energized state.

2 Normative References

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB 4793.1-2007 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements (IEC 61010-1: 2001, IDT)
GB/T 18216.1-2012 Electrical Safety in Low Voltage Distribution Systems up to 1000 V a. c. and 1500 V d. c. - Equipment for Testing, Measuring or Monitoring of Protective Measures - Part 1: General Requirements (IEC 61557-1: 2007, IDT)

3 Terms and Definitions

For the purposes of this document, the definitions given in GB/T 18216.1 and the following terms and definitions apply.

3.1

rated output voltage

UN

voltage output across the measuring equipment terminals when this equipment is loaded with the rated current

Foreword i
1 Scope
2 Normative References
3 Terms and Definitions
4 Requirements
5 Marking and Operating Instructions
6 Tests

Sample only — not a preview of GB/T 18216.2-2012
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 42125.10-2022 in English

    GB/T 42125.10-2022 in English

    Safety requirements for electrical equipment for measurement,control and laboratory use—Part 10: Particular requirements for measurement equipment for insulation resistance and test equipment for electric strength

    2022-10-12
  • GB/T 15946-2008 in English

    GB/T 15946-2008 in English

    Higher performance protocal for the standard digital interface for programmable instrumentation - General

    2008-06-30