《GB/T 18429-2018全封闭涡旋式制冷剂压缩机》由TC238(全国冷冻空调设备标准化技术委员会)归口,主管部门为中国机械工业联合会。
Introduction
GB/T 18429—2018 Standard Background and Evolution
This standard was revised in 2018, replacing the old version from 2001. The main revisions include expanding the scope of application, adding safety requirements and performance test methods.
Main technical content changes
| Old version of the standard | New version of the standard |
|---|---|
| Scope of application is limited to scroll compressors | Covering more refrigerant types, including speed-controlled types |
| Safety requirements are not specified | Safety standards and marking requirements for flammable refrigerants are added |
| Performance tolerance range is relatively wide | Divided into low-temperature, medium-temperature and high-temperature types, with stricter tolerances specified for each type |
Interpretation of technical requirements and test methods
Air tightness test of fully enclosed scroll refrigerant compressor: Use dry nitrogen or air to check to ensure that there is no leakage in the shell. For example, in high-temperature compressors, when the test pressure is not lower than the design pressure, it is necessary to check in a water tank for at least 1 minute.
Performance test method
| Performance index | Test method |
|---|---|
| Volumetric flow rate | Measured according to GB/T 34619 to ensure that the measured value meets the design requirements. |
| Coefficient of performance for cooling/heating | Tested according to GB/T 5773 method under nominal conditions, with a tolerance of no more than ±5%. |
Internal impurities and residual moisture control
For compressors in different power ranges, there are different limits on the internal impurity content and residual moisture. For example, for compressors with a rated power of >8kW, the internal impurity content shall not exceed 1500mg, and the residual moisture shall not exceed 18000mg.
Implementation suggestions
- Manufacturing companies should strictly follow the technical requirements in the standard during the design and production process.
- Carry out a comprehensive inspection before the product leaves the factory, including air tightness and performance testing.
- Strengthen employee training to ensure the correct implementation of the test methods, especially those involving complex testing equipment.
- It is recommended to use the GB/T 13306 standard to make nameplates, and to carry out safety markings in accordance with the requirements of GB/T 9237.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 33224-2016 in English
Environment impact evaluating method on mechanical refrigerating systems used for cooling and heating
2016-12-13 -

GB/T 22068-2025 in English
Electrically driven compressor assembly for automobile air conditioning
2025-01-24 -

GB 25130-2010 in English
Safety requirements for unitary air—Conditioners
2010-09-26 -

GB/T 17758-2023 in English
Unitary air conditioners
2023-11-27 -

GB/T 22069-2024 in English
Gas engine driven air-condition(heat pump)unit
2024-09-29 -

GB/T 25126-2010 in English
Large capacity cross-electromagnetic four-way reversing valve
2010-09-26 -

GB/T 22070-2008 in English
Aqua-ammonia absorption refrigerating unit
2008-07-01 -

GB/T 19409-2013 in English
Water-source (Ground-source) Heat Pumps
2013-12-17 -

GB/T 37123-2018 in English
Electrically driven motor vehicl eair-conditioning unit
2018-12-28 -

GB/T 41660-2022 in English
The survey-evaluating method of energy utilization for refrigeration test systems
2022-07-11