《GB/T 19889.7-2022声学 建筑和建筑构件隔声测量 第7部分:撞击声隔声的现场测量》由TC17(全国声学标准化技术委员会)归口,主管部门为中国科学院。
Introduction
Analysis of the core content of the standard
GB/T 19889.7-2022 is an important standard for building acoustics measurement. It replaces the 2005 version and integrates the relevant content of GB/T 19889.14-2010. The standard specifies the method of measuring the sound insulation performance of floor impact sound in the frequency range of 50Hz-5000Hz using two excitation sources: impactor and rubber ball.
Key Technology Updates
- Expanded Measurement Range: Added rubber ball as a heavy and soft impact sound source, and improved the assessment of daily noise such as barefoot walking
- Enhanced low-frequency measurement: For rooms with a volume of less than 25m³, it is required to add 50/63/80Hz corner sound pressure level measurement
- Detailed Operation Specifications: It is clearly stated that when measurement personnel are present, they must maintain a distance of ≥1 arm's length from the microphone
Measurement Equipment and Calibration Requirements
| Equipment Type | Standard Basis | Calibration Period | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sound Pressure Level Measurement System | GB/T 3785.1 Key Points for Implementation of Field MeasurementSpecialization of Impact Source ArrangementFor impactor: At least 4 positions shall be randomly distributed, ≥0.5m from the floor boundary, and the hammer connection line shall be at a 45° angle to the beam. Soft surface layers shall adopt the special requirements of Appendix A. For rubber ball: free fall from a height of 100cm±1cm, the lightweight floor must include the top and center points of the joists. Comparison of Microphone Arrangement Schemes
Special Requirements for Low-Frequency Band MeasurementsWhen the volume of the receiving room is less than 25m³, the following additional measurements are required based on conventional measurements:
Note: For reverberation time measurement, a 63Hz octave filter is used to improve the measurement accuracy of small rooms. Result Expression and UncertaintyThe test report must include: