Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
geothermal power plant power network introduction interpretation geothermal power stations geothermal power plants geothermal power generation technology reactive power regulation set plates cement strength scopethis document air conditioning devices
GB/T 19962-2016 in English

GB/T 19962-2016 in English

VALID

Technical rule for connecting geothermal power plant power network

  • Issued on:2016-08-29
  • Implemented on:2017-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $120.00
$117.00
Standard No: GB/T 19962-2016
Document status: VALID
Superseded by: GB/T 19962-2026 Technical requirements for connecting geothermal power station to power system
Superseded on: 2027-02-01
Title in English: Technical rule for connecting geothermal power plant power network
Title in Chinese: 地热电站接入电力系统技术规定
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2016-08-29
Implemented on: 2017-03-01
Superseding: GB/T 19962-2005 Techical rule for connecting geothermal power plant to power netwrok
ICS Classification: 27.180-Wind turbine systems and other alternative sources of energy
Chinese Classification: F15-Geothermal energy
Professional Classification: GB-National Standard
Related Keywords: geothermal power plant power network introduction interpretation
geothermal power stations
geothermal power plants
geothermal power generation technology
reactive power regulation
Related Topics: power station
Geothermal Power Generation Technology
GB/T 19962-2016
Power station test system
GBT19962
GBT19962-2005
GBT19962-2016
Technical specification requirements for electronic letter of guarantee system access
gb/t 19962-2019
Ground box technology for power cable lines

《GB/T 19962-2016地热电站接入电力系统技术规定》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


Introduction

Interpretation of the National Standard of the People's Republic of China GB/T 19962—2016

1. Standard background and revision instructions

This standard replaces GB/T 19962—2005, mainly adding technical requirements such as active power, reactive capacity, and voltage control, and deleting contents such as power balance and flow calculation. The following is a comparison between the new and old versions:

Technical requirements 2005 version 2016 version
Active power control Not explicitly required Newly added, requiring participation in frequency regulation and peak regulation
Reactive capacity configuration Briefly mentioned Detailed provisions on the principle of layered and zoned compensation
Voltage control range Not explicitly required Newly added, clarifying the voltage control standard for grid connection points

2. Standard Framework and Technical Requirements

2.1 Scope of application

This standard applies to geothermal power stations connected to the power system through $35~\mathrm{kV}$ and above voltage level lines, including new construction, reconstruction and expansion projects. Power stations of other voltage levels can refer to it.

2.2 Main technical requirements

The standard covers the following key indicators:

  • Active power regulation capability: The normal regulation rate of the unit should not be less than $1\%$ of the rated power per minute.
  • Reactive capacity configuration: Layered and zoned compensation is required to ensure system voltage stability.
  • Voltage control range: The voltage at the grid connection point should be controlled between $97\% \sim 107\%$ of the nominal voltage.
  • Power quality: Meet the requirements of GB/T 12325 and GB/T 12326.

3. Implementation suggestions and precautions

3.1 Design stage

During the design stage of geothermal power plants, the following aspects should be focused on:

  • Voltage level selection: According to the current status of the power grid and the demonstration of future development scale, it is recommended to give priority to the voltage level of $35~\mathrm{kV}$ and above.
  • Wiring method: Multiple geothermal power plants should adopt the method of stepping up and sending out after aggregation to improve the operating efficiency of the system.

3.2 Operation and maintenance stage

During the operation and maintenance stage, the following matters should be noted:

  • Reactive power regulation: The generator set should have the ability to dynamically adjust the power factor (leading $0.95 \sim$ and lagging $0.9$) when operating at rated power.
  • Voltage control: Ensure that the voltage at the grid connection point is within the normal range to avoid exceeding the voltage and causing grid fluctuations.

4. Standard significance and future prospects

The release of GB/T 19962-2016 marks the standardization and maturity of geothermal power generation technology in my country. With the advancement of renewable energy technology, future standards will focus on optimizing the following aspects:

  • Intelligence: Promote the application of automation and intelligent control technology.
  • Compatibility: Improve the adaptability and interoperability of geothermal power stations and power grids.
  • Environmental protection: Strengthen technical requirements for power quality and environmental impact.

Sample only — not a preview of GB/T 19962-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.