GB/T 20975.5-2020 in English
VALIDMethods for chemical analysis of aluminium and aluminium alloys—Part 5:Determination of silicon content
- Issued on:2020-06-02
- Implemented on:2021-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
《GB/T 20975.5-2020铝及铝合金化学分析方法 第5部分:硅含量的测定》由TC243(全国有色金属标准化技术委员会)归口,TC243SC1(全国有色金属标准化技术委员会轻金属分会)执行,主管部门为中国有色金属工业协会。
Introduction
Standard Overview and Technical Evolution
GB/T20975.5-2020 replaces the 2008 version of the standard. The main updates include: Expansion of measurement range (upper limit of spectrophotometry increased from 0.40% to 15.00%), Strengthening of safety warnings, Revision of precision data and Adjustment of sample weighing table. This standard keeps pace with the relevant ISO methods and reflects the technological progress in the field of non-ferrous metal analysis in my country.
Comparison of Method Principles
| Dimensionality | Molybdenum blue spectrophotometry | Gravimetric method |
|---|---|---|
| Measurement range | 0.0010%-15.00% | 10.00%-63.00% |
| Principle | Silico-molybdenum heteropoly acid reduction color development, 650-810nm absorbance measurement | Perchloric acid dehydration weighing SiO₂, hydrofluoric acid volatilization subtraction method |
| Key reagents | Ammonium molybdate, 1-amino-2-naphthol-4-sulfonic acid | Perchloric acid, hydrofluoric acid |
| Applicable scenarios | Low-content samples, batch testing | High-content arbitration analysis |
Core operating points
Molybdenum blue spectrophotometry
- Sample dissolution uses a polytetrafluoroethylene beaker, sodium hydroxide-hydrogen peroxide system
- The acidification stage needs to strictly control the color development acidity of pH≈0.9
- After color development, the determination must be completed within 30 minutes to prevent complex decomposition
Gravimetric method
- The dehydration process needs to maintain Platinum crucibleConstant weight state
- Sulfuric acid needs to be added during hydrofluoric acid treatment to prevent volatilization of other elements
- Constant weight needs to be achieved when burning at 1000℃ (mass change ≤0.0002g)
Precision control
The standard provides strict repeatability (r) and reproducibility (R) requirements:
- Spectrophotometry r=0.0004%, R=0.0008% at 0.001% content
- Gravimetric method r=1.00%, R=1.10% at 50% content
The laboratory should regularly use standard substances to verify the precision of the method.
Implementation suggestions
Case: An aluminum alloy factory detected a silicon content of 11.25%, and the result of the gravimetric method was 11.18%-11.32%, which met the standard requirement of r=0.38%. Key control points:
- The perchloric acid dehydration time is strictly controlled within 15-20 minutes
- Use medium-speed quantitative filter paper for filtration and wash until neutral
- Operate in a fume hood when treating with hydrofluoric acid
For samples with a boundary content of 10%-15%, it is recommended to use the gravimetric method as the arbitration method.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 4949-2026 in English
Chemical analysis methods for sacrificial anode of Al-Zn-In system alloy
2026-01-28