Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
technical requirements dry-type amorphous alloy core distribution transformers dry-type amorphousalloy core distribution transformers introduction amorphous alloy core transformers three-phase dry-type amorphous alloy core tri-axial creep test method scopethis part capillary absorption properties virtual private line service scopethis section
GB/T 22072-2018 in English

GB/T 22072-2018 in English

VALID

Specifications and technical requirements for dry-type amorphousalloy core distribution transformers

  • Issued on:2018-12-28
  • Implemented on:2019-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: GB/T 22072-2018
Document status: VALID
Title in English: Specifications and technical requirements for dry-type amorphousalloy core distribution transformers
Title in Chinese: 干式非晶合金铁心配电变压器技术参数和要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-12-28
Implemented on: 2019-07-01
Superseding: GB/T 22072-2008 Specifications and technical requirements for dry-type amorphous alloy core distribution transformers
ICS Classification: 29.180-Transformers. Reactors
Chinese Classification: K41-Transformer
Professional Classification: GB-National Standard
Related Keywords: technical requirements
dry-type amorphous alloy core distribution transformers
dry-type amorphousalloy core distribution transformers introduction
amorphous alloy core transformers
three-phase dry-type amorphous alloy core
Related Topics: Technical Parameters
Amorphous Alloy Standard
Air pressure technical parameters
Prototype Technical Parameters
distribution transformer
GB/T 22072
gb22072
gb/t22072-2018
GB/T 22072-2018
GB/t+22072
gb/t22072
Flow Technical Parameters
GBT22072
GB/T 22072-2008
GB/T 22072-2018
Technical parameters and requirements of dry-type transformers for photovoltaic power generation
Dry-type power transformer supply technical requirements
SAJ inverter control mode parameters
GB/T 10228-2023 Technical parameters and requirements for dry-type power transformers
Amorphous alloy transformer technology
Distribution, dry type transformer
Amorphous alloy transformer core technology
Amorphous technology
Amorphous alloy powder technical standards
gb/t22072-2008
Dry-type transformer charging requirements

《GB/T 22072-2018干式非晶合金铁心配电变压器技术参数和要求》由TC44(全国变压器标准化技术委员会)归口,主管部门为中国电器工业协会。


Introduction

1. Standard Overview

GB/T 22072-2018 "Technical Parameters and Requirements for Dry-type Amorphous Alloy Core Distribution Transformers" is a national standard of the People's Republic of China, which specifies the terms and definitions, performance parameters, technical requirements, etc. of dry-type amorphous alloy core distribution transformers. This standard is applicable to indoor three-phase dry-type amorphous alloy core non-excitation voltage-regulating distribution transformers with system nominal voltages of 6kV, 10kV, 20kV and 35kV.

2. Comparison of standard frameworks

Standard version Applicable voltage level (kV) Main technical changes Description of modified content
GB/T 22072—2018 6, 10, 20, 35 Added performance parameters and sound level levels of 20kV and 35kV products Adjusted normative references, no-load current and sound level
GB/T 22072—2008 6, 10 - Technical requirements for 20kV and 35kV products are not included

3. Implementation Suggestions

When selecting amorphous alloy core transformers, focus on the following factors:

  • Select a transformer with appropriate capacity according to load requirements
  • Ensure that the transformer meets the requirements of GB/T 1094.11 and GB/T 1094.12
  • In high temperature or high humidity environments, pay attention to the measurement and protection of insulation resistance values

4. Analysis of Technological Evolution

From GB/T 22072-2008 to GB/T 22072-2018, the main technical improvements include:

  • Added support for higher voltage levels (20kV and 35kV)
  • Optimized control of no-load current and sound level
  • Improved accuracy of load loss calculation

Sample only — not a preview of GB/T 22072-2018