Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
technical requirements technical parameters above oil-immersed shunt reactors introduction interpretation level oil tank wall amplitude ≤100μm oil storage cabinet thermal insulation materials low concentration particulate matter carbon series
GB/T 23753-2020 in English

GB/T 23753-2020 in English

VALID

Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors

  • Issued on:2020-11-19
  • Implemented on:2021-06-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $690.00
$670.00
Standard No: GB/T 23753-2020
Document status: VALID
Title in English: Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors
Title in Chinese: 110kV及以上油浸式并联电抗器技术参数和要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2020-11-19
Implemented on: 2021-06-01
Superseding: GB/T 23753-2009 Specification and technical requirements for 330kV and 500kV oil- immersed shunt reactors
ICS Classification: 29.180-Transformers. Reactors
Chinese Classification: K41-Transformer
Professional Classification: GB-National Standard
Related Keywords: technical requirements
technical parameters
above oil-immersed shunt reactors introduction interpretation
level oil tank wall amplitude ≤100μm
oil storage cabinet
Related Topics: Technical Parameters
gb23753
GB/T 23753-2009
rbdp baseband digital parallel
gb/t23753
GB/T 23753--2009
GB/T 23753
GB/t+23753
Prototype Technical Parameters
GB 23753
Technical Parameters
oil immersion
Reactor
gb+23753
GB/t+23753+
in parallel
rbdp baseband digital parallel
Oil-immersed shunt reactor
Flow Technical Parameters
Reactor voltage
shunt reactor
"Reactor"
GBT23753
GB/T 23753-2009
GB/T 23753-2020
oil immersion
Anti-crack technical parameters
gb/t23753-2020

《GB/T 23753-2020110kV及以上油浸式并联电抗器技术参数和要求》由TC44(全国变压器标准化技术委员会)归口,主管部门为中国电器工业协会。


Introduction

Interpretation of the core content of the standard

Voltage levelCapacity range (Mvar)Insulation level (kV)Sound level limit (dB)
110kV10-80480/20080
220kV10-120950/39580
330kV10-1501175/51080
500kV30-1801550/68075
750kV60-1802100/90080
1000kV160-4002250/110080

Key technical requirements

1. Reactance value deviation: Rated reactance allowable deviation ±5%, phase-to-phase deviation ≤±2% 2. Overexcitation capability: 1.15 times the voltage can last for 60-120 minutes (different levels vary) 3. Partial discharge: 1000kV level requires ≤100pC (high voltage end) and ≤300pC (neutral point end) 4. Vibration control: 750/1000kV level oil tank wall amplitude ≤100μm (peak value)

Structural design points

  • Use metal corrugated sealed oil storage cabinet to prevent oil aging
  • 750kV and above require a three-dimensional impact recorder
  • 1000kV bushing pollution level ≥ 4, creepage distance ≥ 25mm/kV
  • Neutral point grounding reactor needs to pass 50kPa vacuum verification

Implementation suggestions

  1. External insulation distance should be revised according to GB/T 1094.3 in high altitude areas
  2. 1000kV equipment transportation should maintain 20-30kPa positive pressure nitrogen protection
  3. It is recommended to add polarization index test as a quality monitoring indicator
  4. Oil chromatography analysis needs to include special detection of acetylene content

Sample only — not a preview of GB/T 23753-2020