Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
low-voltage switchgear temperature rise verification method controlgear assemblies calculation scopethis standard generalized method cad software rectification equipment pulp types
GB/T 24276-2017 in English

GB/T 24276-2017 in English

SUPERSEDED

A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation

  • Issued on:2017-11-01
  • Implemented on:2018-05-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $430.00
$418.00
Standard No: GB/T 24276-2017
Document status: SUPERSEDED
Superseded by: GB/T 24276-2025 A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation
Superseded on: 2026-07-01
Title in English: A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation
Title in Chinese: 通过计算进行低压成套开关设备和控制设备温升验证的一种方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2017-11-01
Implemented on: 2018-05-01
Superseding: GB/T 24276-2009 A method of temperature-rise assessment by extrapolation for partially type-tested assemblies(PTTA)of low-voltage switchgear and controlgear
Chinese Classification: K31-Low-voltage distribution electrical equipment
Professional Classification: GB-National Standard
Related Keywords: low-voltage switchgear
temperature rise verification method
controlgear assemblies
calculation scopethis standard
generalized method
Related Topics: Method of Temperature Rise Verification
Do 2 warm-ups
five algorithms
channel verification device
By what method to verify?
Heating process
Heat jacket temperature calculation
Class I equipment verification
GB24276
GBT24276
GB/T 24276-2009
GB/T 24276-2017
gb7251.1-2013 Low voltage complete switchgear
Computer special equipment related industries
Temperature rise verification method
Design verification using experimental methods
Acceptance of low voltage complete sets of switchgear
Design ideas and preparation methods of antibody enzymes
Pressure rise rate calculation method
Design through superposition and separation
Low voltage switchgear implementation
Controller temperature rise test
gb/t 24276
High and low temperature integrated temperature control equipment

《GB/T 24276-2017通过计算进行低压成套开关设备和控制设备温升验证的一种方法》由TC266(全国低压成套开关设备和控制设备标准化技术委员会)归口,主管部门为中国电器工业协会。


Scope

This standard specifies a method for verifying the temperature rise of low-voltage switchgear and controlgear assemblies by calculation. This method is applicable to enclosed switchgear or partitioned cabinet units of switchgear without forced ventilation, but not to situations where the relevant product standard GB/T 7251 explicitly specifies a temperature rise verification method. Note 1: The material and wall thickness of the enclosure can generally have some influence on the steady-state temperature. However, the generalized method used in this standard ensures its applicability to enclosures made of steel, aluminum, cast iron, insulation, and similar materials. The recommended method is intended to determine the temperature rise of the air inside the enclosure. Note 2: The air temperature inside the enclosure is equal to the ambient air temperature outside the enclosure plus the air temperature rise inside the enclosure due to the power losses of the installed equipment. Unless otherwise specified, the ambient air temperature outside the switchgear is the air temperature at the installation location at 35°C (above the 24-hour average). If the ambient air temperature at the location where the switchgear is used exceeds 35°C, this higher temperature is considered the ambient air temperature.

Sample only — not a preview of GB/T 24276-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.