Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
maintenance failure coding failure maintenance information code classification failure maintenance information code failure coding system failure maintenance information code appendix a other rubber products tourism performances petroleum drilling engineering scopethis standard
GB/T 24822-2009 in English

GB/T 24822-2009 in English

VALID

The specifications for maintenance failure coding of household and similar electrical appliances

  • Issued on:2009-12-15
  • Implemented on:2010-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $250.00
$243.00
Standard No: GB/T 24822-2009
Document status: VALID
Title in English: The specifications for maintenance failure coding of household and similar electrical appliances
Title in Chinese: 家用和类似用途电器维修故障编码规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2009-12-15
Implemented on: 2010-05-01
ICS Classification: 97.030-Domestic electrical appliances in general
Chinese Classification: Y60-Basic standards and general methods for household appliances
Professional Classification: GB-National Standard
Related Keywords: maintenance failure coding
failure maintenance information code
classification failure maintenance information code
failure coding system
failure maintenance information code appendix a
Related Topics: Fault
error code
Various encoders
How to code the fault type
GBT24822
GB/T 24822-2009
Household and similar electrical appliances
Household and similar uses
Repair failure
error code
Common to all countries with malfunctions
Spectrometer troubleshooting methods
Colorimeter troubleshooting methods
Texture analyzer troubleshooting methods

《GB/T 24822-2009家用和类似用途电器维修故障编码规范》由TC46(全国家用电器标准化技术委员会)归口,主管部门为中国轻工业联合会。
本标准规定了家用和类似用途电器产品售后服务过程中所涉及到的信息来源、故障现象、服务类型、服务方式、故障原因、维修措施以及故障责任的信息编码及规则。
本标准适用于家用和类似用途电器售后服务过程中所涉及到的信息编码。


1 General

This standard specifies information coding of information source, failure phenomenon, service types, service modes, failure cause, maintenance measures and responsibility for failure involved in the process of after sales service of household and similar electrical appliances.
This standard is applicable to the information coding involved in the process of after sales service of household and similar electrical appliances.

2 Terms and Definitions

For the purpose of this standard, the following terms and definitions apply.
2.1
Coding
The process of convert the information into code according to certain protocols or formats.
2.2
Number code
The numeric character set (0 to 9) served as the significant character of each code position.
2.3
Letter code
Capital or lowercase English letter character set (A to Z, or a to z) served as the significant character of each code position. Generally, mixed application of capitalization capital and lowercase letters is not permissible.
2.4
Mixed code
Mixed application of numeric character set and alphabetic character set simultaneously and served as the significant character each code position.

3 Failure Coding System

3.1 Failure coding system is mainly used to record the coding of correlative and interactive key information which involved in the service process, include: user information code product information code, failure maintenance information code, accessories information code, etc.
3.2 User information code records the relevant information of user, mainly include: country and region, name, telephone, postbox, address, post code, etc.
3.3 Product information code records the relevant information of product, mainly include: product, series, type, delivery number, date of acquisition, installation date, date of repair request, etc.
3.4 Failure maintenance information code records the relevant information of service process and result, mainly include: information source, failure phenomenon, service type, service mode, failure cause, maintenance measures and responsibility for failure, etc.
3.5 Accessories information code records the relevant information of used accessories in the process of service, mainly include: accessories name, accessories coding, etc.

4 Coding Rules of Failure Maintenance Information Code

4.1 Classification
Failure maintenance information code include 8 types in total: information source code, status code, symptom code, service type code, service mode code, failure code, maintenance code and responsibility code.
4.2 Information source code
4.2.1 Information source code is universal coding used to indicate user's type of required service.
4.2.2 Information source code is single-bit numerical code, which classified into 4 types in total, see Table 1.
Table 1 Info

Foreword I
1 General
2 Terms and Definitions
3 Failure Coding System
4 Coding Rules of Failure Maintenance Information Code
Appendix A (Normative) Maintenance Coding System- Status Code List
Appendix B (Normative) Maintenance Coding System - Extended Status Code List
Appendix C (Normative) Maintenance Coding System - Symptom Code List
Appendix D (Normative) Maintenance Coding System - Failure Code List
Appendix E (Normative) Maintenance Coding System - Maintenance Code List

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend