Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
reduced-pressure type backflow preventer introduction core changes backflow preventer dn100 backflow preventer basic terms new definition key technical requirements stressed components introductionthis standard explosive spray coatings digital photographic records scopethis standard
GB/T 25178-2020 in English

GB/T 25178-2020 in English

VALID

Reduced-pressure type backflow preventer

  • Issued on:2020-12-14
  • Implemented on:2020-12-14
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $310.00
$301.00

《GB/T 25178-2020减压型倒流防止器》由TC434(全国城镇给水排水标准化技术委员会)归口,主管部门为住房和城乡建设部。


Introduction

Core changes in the standard revision

Technical elements 2010 edition 2020 edition
Definition of terms 5 basic terms New definition of "starting discharge pressure difference", deleted 2 redundant terms
Structural requirements Dispersed clauses Integrated into Chapter 5, strengthen the arrangement requirements of detection ball valves
Performance indicators 7 basic requirements Add 4 new indicators such as cycle test and hygiene requirements

Analysis of key technical requirements

1. Structural design specifications

The standard requires that the backflow preventer must be equipped with:

  • 2 independently acting check valves (without mechanical linkage)
  • 4 equal-diameter detection ball valves (position see standard clause 5.2.3)
  • Equipment above DN50 must be equipped with a removable valve cover

2. Key performance indicators

Typical case: During the factory inspection of a DN100 backflow preventer, when the water inlet chamber pressure P1=0.2MPa:

  • The intermediate chamber pressure P2=0.6MPa

    class=instrument>P2needs ≤0.186MPa (pressure difference ΔP ≥ 14kPa)
  • The starting pressure difference of the drain valve should be ≥14kPa
  • The pressure loss under zero flow state is ≤60kPa

Implementation suggestions

1. Control of the manufacturing process

Key points:

  1. The shell wall thickness should meet the requirements of GB/T26640
  2. Rubber seals must pass GB/T21873 sanitary certification
  3. Painting adhesion ≥8MPa (GB/T5210 test)

2. Inspection precautions

Type test needs to be completed:

  • 5000 opening and closing cycle tests (25%-100% flow classification)
  • 50kPa vacuum siphon test (lasting 5min)
  • Pressure fluctuation ±10kPa stability verification