GB/T 26017-2020 in English
VALIDHigh purity copper
- Issued on:2020-09-29
- Implemented on:2021-08-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$117.00
《GB/T 26017-2020高纯铜》由TC243(全国有色金属标准化技术委员会)归口,TC243SC2(全国有色金属标准化技术委员会重金属分会)执行,主管部门为中国有色金属工业协会。
Introduction
Analysis of Standard Technology Evolution
The 2020 version of the standard added two ultra-high purity grades, HPCu-7N and HPCu-6N5, with copper purity reaching 99.99999% and 99.99995% respectively, reflecting the semiconductor industry's extreme requirements for material purity. Compared with the 2010 version, the main technological breakthroughs are reflected in:
| Technical Dimension | GB/T 26017-2010 | GB/T 26017-2020 | Significance of Upgrade |
|---|---|---|---|
| Purity Grade | Up to 6N | New 7N Grade | Meet the Demand of 5nm Process Chips |
| Element Control | 23 Impurities | New Cl Element Control | Preventing Integrated Circuit Corrosion |
| Detection Method | Including Appendix A | Using YS/T 922 uniformly | Improve detection consistency |
Analysis of key indicators
HPCu-7N has 5-10 times stricter limits on key impurities such as Ag and Fe than 6N, including:
- Ag≤0.05ppm (0.3ppm for the 2010 version)
- Fe≤0.01ppm (0.1ppm for the 2010 version)
- Added control requirements for Cl≤1ppm
Application implementation suggestions
Sputtering target selection plan
8-inch wafer manufacturing recommends the use of HPCu-6N5 grade, 12-inch wafers need to use HPCu-7N grade. Ningbo Jiangfeng Electronics' measured data shows that 7N copper target can reduce the film resistivity by 15%.
Packaging and transportation specifications
Aluminum-plastic bag vacuum packaging + nitrogen protection must be used, and the transportation environment humidity should be ≤40%RH. The case of Jinchuan Group shows that improper packaging will cause the surface oxide layer to thicken by 3nm.
Optimization of detection method
The new version cancels the glow discharge mass spectrometry appendix and uniformly adopts the YS/T 922 standard. The detection process should pay attention to:
- The sample needs to be pretreated with 1:1 nitric acid solution
- The cleanliness of the detection room must reach Class 100
- The resolution of the mass spectrometer should be ≥10,000

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 26311-2024 in English
Rod, bar and wire of recycling copper and copper alloy
2024-09-29 -

GB/T 2529-2012 in English
Copper sheets and bars for electrical conduction purpose
2012-12-31 -

GB/T 30852-2014 in English
Conductive copper and copper alloy profile for the traction motors
2014-07-24 -

GB/T 36146-2018 in English
Rolled copper foil for lithium ion battery
2018-05-14 -

GB/T 23609-2023 in English
Seamless copper alloy tube for water desalting applications
2023-08-06 -

GB/T 14594-2014 in English
Oxygen-free copper sheets and strips for vacuum electron devices
2014-12-05 -

GB/T 5187-2021 in English
Liquid chlorine for industrial use
2021-08-20 -

GB/T 13587-2020 in English
Scraps of copper and copper alloy
2020-09-29 -

GB/T 17791-2017 in English
Seamless copper and copper alloys tube forair conditioner and refrigeration equipment
2017-07-12