GB/T 32505-2016 in English
VALIDVariable-frequency drive for machine tool
- Issued on:2016-02-24
- Implemented on:2016-09-01
- File Format:PDF
- Delivery:Via email within 5 business days
$359.00
《GB/T 32505-2016机床专用变频调速设备》由TC518(全国变频调速设备标准化技术委员会)归口,主管部门为中国电器工业协会。
Introduction
Analysis of the core content of the standard
This standard applies to machine tool variable frequency speed regulation equipment with a rated input voltage ≤1kV and an output frequency <600Hz, and puts forward unified technical requirements for voltage source type and current source type equipment.
Comparison of key technical indicators
| Project | V/f control | Vector control | DTC control |
|---|---|---|---|
| Speed accuracy | ≤0.5% | ≤0.02%(with PG) | ≤0.02% |
| Starting torque | ≥150% rated torque (at 1Hz) | ||
| Efficiency requirement | 30kVA or above ≥95% | ||
Key requirements for electromagnetic compatibility
According to GB 12668.3-2012:
- Radiated disturbance: 30-230MHz frequency band ≤50dB(μV/m)
- Conducted disturbance: 0.15-0.5MHz≤100dB(μV)
- Electrostatic discharge: contact discharge 4kV/air discharge 8kV
The inverter needs to pass the 10 immunity tests specified in Appendix A.
Implementation suggestions
- Pay attention to the overload capacity indicator when selecting: 180% rated current for 1 minute
- Installation environment requirements: Derating is required for altitudes > 1000m
- Required items for acceptance testing: temperature rise test (semiconductor device shell temperature rise ≤ 45K)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 30843.1-2024 in English
Variable-frequency drive above 1 kV and not exceeding 35 kV—Part 1: Technical conditions
2024-12-31 -

GB/T 31487.2-2025 in English
Direct current deicers—Part 2: Converters
2025-12-31 -

GB/T 32515-2016 in English
Variable-frequency drive for injection molding machine
2016-02-24