Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
plasma mass spectrometry coupled plasma mass spectrometer trace elements various trace elements mass spectrometer cad standard parts scopethis standard mobile drilling rigs digital electrocardiographs scopethis type evaluation outline
GB/T 32650-2016 in English

GB/T 32650-2016 in English

VALID

Determining the content of trace elements in arenaceous quartz by inductively coupled plasma mass spectrometry(ICP-MS)

  • Issued on:2016-04-25
  • Implemented on:2016-11-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $100.00
$97.00
Standard No: GB/T 32650-2016
Document status: VALID
Title in English: Determining the content of trace elements in arenaceous quartz by inductively coupled plasma mass spectrometry(ICP-MS)
Title in Chinese: 电感耦合等离子质谱法检测石英砂中痕量元素
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2016-04-25
Implemented on: 2016-11-01
Professional Classification: GB-National Standard
Related Keywords: plasma mass spectrometry
coupled plasma mass spectrometer
trace elements
various trace elements
mass spectrometer
Related Topics: Precursor ion peak in mass spectrum
MS ionization voltage
inductance
Mass Spec + Precursor Ion Peak
mass coupling
Inductively Coupled Plasma Mass Spectrometry
Inductive plasma mass spectrometer
ion trap trace
Trace detection method
mass spectrometry field ionization
Mass Spectrometry Ionization Species
Bromine Mass Spectrometry
plasma mass spectrometry
Mass Spectrum Molecular Weight
Quality Inspection Center Telephone
Inductive coupling general purpose
Ferrous inductive coupling
ion pairs in mass spectrometry
plasma mass spectrometry
Quartz sand inspection report
Precursor Ions in Mass Spectrometry
Elemental Analysis Ions
Plasma inductive coupling
Three Inductive Coupling
Element Molecular Weight
Inductively Coupled Plasma Characterization
Mass spectrometric detection of transitions
Mass Spec Ion Hydrazine
field ionization mass spectrometry
Inductively Coupled Plasma
plasma detection
Inductively Coupled Plasma Mass Spectrometry Manganese
mass spectrometry ion spectrum
Inductive coupling detection
mass spectrometer plasma
Inductively Coupled Mass Spectrometry Lithium
The molecular weight in the mass spectrum is more than 7
58 ions in the mass spectrum
Mass Spectrum Molecular Weight 26
plasma mass spectrometry
plasma coupling
How to detect inductive coupling disk
Inductively Coupled Plasma Rhodium
Fe ion mass spectrometry
Mass Spectrum Molecular Weight 43
Coupled inductor.co
Determination of trace elements in water
mass spec ion peak mass
Detection of a small amount of deuterium
as element
Mass Spectrum Molecular Weight 36
Inductively Coupled Plasma Mass Spectrometry
Mass spec b-ions
Inductively Coupled Plasma Characterization
element concentration in solution
Detection of multiple elements in ore
precursor ion mass
British mass spectrometry
English for mass spectrometry
Deuterium content in water by mass spectrometry
plasma coupled mass spectrometry
ion mass spectrometry
Ions in a mass spectrum
Major ions in mass spectrometry
Mid-spectrum detection+
Inductive Plasma Mass Spectrometry
British mass spectrometer
Quantity of product ions in mass spectrometry
Detecting Transitions in Mass Spectrometry
Mid-spectrum detection
MS ionization voltage
plasma mass spectrometry
MS ion cluster
atomic detection element
ion mass spectrometry
Element Energy Spectrum
Mass Spectrum Peak Precursor Ion
Ions in mass detection
Ion Elemental Analysis
Ion peaks in a mass spectrum
Ore element detection
Voltage ionization + mass spectrometry
trace trace elements
Measurement of Trace Elements by Mass Spectrometry
Detection center ion
Inductively Coupled Plasma Quartz
Ion Hydrazine Mass Spectrometry
trace detection
Peptide + MS Ionization
plasma detection
Ore element detection
Plasma coupled mass spectrometer
Gold ore element detection
Gold ore element detection
Inductively Coupled Plasma Dual Mass Spectrometry
Measure element method
inductively coupled ions
Induced ions
Inductively coupled plasma
Inductively coupled plasma
Inductively Coupled Plasma Mass Spectrometry Sample Preparation
Precursor ion peaks in mass spectra
sub-mass detection
Mass Spectrometry Precursor Ion Peak
Uncoupled Inductor
Ion source in mass spectrometry
The molecular weight in the mass spectrum is more than 54
trace lead element
Mass Spec + Precursor Ion Peak
icpms inductively coupled plasma mass spectrometry
Major Ions in Mass Spectrometry
Mass Spectrometry Ion Detection
Mass Spectrometry Primary Ionization
ancient trace elements
Separation of trace compounds
Organic Mass Spectrometry Sodium
Used ICP-MS
MS coupled peaks
质谱中分子量多44
Atomic mass detection
Elemental electron energy
Ion Elemental Analysis
Mass Spectrometry Ionization Technology
Inductive coupling test
Inductively Coupled Plasma Mass Spectrometry for Lead in Water
Talc powder inductively coupled plasma mass spectrometry
Dual Inductive Coupling
Determination of 24 Elements in Soil by Inductively Coupled Plasma Mass Spectrometry
Precursor ion mass for mass spectrometry
Mass spectrometry detection sample volume
Ion content in mass spectrometry
Element Energy Spectrum
molecular weight element
Atomic element detection
Element Molecular Weight
Zhongrui Quartz
Element detection in ore
Inductively Coupled Ion Mass Spectrometry
Trace elements and trace elements
mass spectrometry ion element
Inductively Coupled Ion Mass Spectrometry
GBT32650
GB/T 32650-2016
CuTiTantalum Inductively Coupled Plasma Mass Spectrometry
Inorganic Inductively Coupled Plasma Mass Spectrometry
Mass spectrometry APCI ion source measures substance molecular weight +36
Inventor of mass spectrometry soft ionization
Detection of Antibiotics by Ion Chromatography
Inductively coupled plasma mass spectrometer won the bid
Mass Spectrometry 4500 Split Ion Source
In the mass spectrum if the mass of the precursor ion m1 and the product ion m2
PE inductively coupled plasma mass spectrometer won the bid
Plasma assay for iron element
The role of ion detectors in mass spectrometers
Mass spectrometry soft ionization method
Optocoupler component quality grade
Ordinary quartz sand quality
Trace Element Detection Methods Mass Spectrometry Pharmacopoeia
Quartz sand carbon content detection method
Trace substance detection
Quartz sand testing
Measurement method of rubidium in quartz sand
Detection of elemental carbon in sludge
Quartz sand impurity detection method
Trace element calcium ion detection method
Quartz sand detection method
Phosphorus element standard mass spectrum
Quartz sand acid resistance testing method
Mass spectrometry detection
Detection method of sodium in quartz sand
Determination method of iron element in electronic grade quartz sand
Trace test
Element homogeneity test

《GB/T 32650-2016电感耦合等离子质谱法检测石英砂中痕量元素》由TC203(全国半导体设备和材料标准化技术委员会)归口,主管部门为国家标准化管理委员会。


Introduction

1. Background and significance of the standard

GB/T32650-2016 standard is a detection method for trace elements in quartz sand, which uses inductively coupled plasma mass spectrometry (ICP-MS) for determination. This method is suitable for the quantitative analysis of various trace elements such as aluminum, calcium, iron, sodium, potassium, etc. in quartz sand, and provides an important technical basis for the quality control of semiconductor materials and related products.


2. Principle and technical route of the method

Inductively coupled plasma mass spectrometry (ICP-MS) is an efficient and sensitive elemental analysis technology. After the sample is digested with hydrofluoric acid and treated with nitric acid medium, it is introduced into the ion source through a nebulizer, and positively charged ions are formed through evaporation, dissociation, atomization and ionization.

The mass spectrometer separates ions according to the mass-to-charge ratio (m/z). The integrated area is proportional to the number of ions. The calibration curve is established through a standard series of solutions to achieve quantitative analysis of trace elements in the sample.

Inductively coupled plasma mass spectrometer (ICP-MS) consists of an ion source and a mass spectrometer and is the core equipment of this method.

3. Interference factors and solutions

The interference factors mainly include diatomic ions, polyatomic ions, matrix effects, background noise, and interactions between elements. In addition, the purity of reagents and the cleanliness of equipment will also affect the test results.

To reduce interference, the standard stipulates the use of high-purity reagents and strict control of laboratory environmental conditions (temperature 20℃±2℃, humidity 45%~55%, and air cleanliness of level 6 or above).


4. Comparison of standard frameworks

Standard requirements GB/T32650-2016 Comparison with international standards
Scope of application Determination of 13 trace elements in quartz sand Basically consistent with ISO standard methods
Reagent requirements Ultrapure water (resistivity ≥18MΩ·cm) In line with international laboratory water standards
Analysis accuracy Detection limit range: 0.3~7.0 ng/g Better than some similar international methods

5. Implementation suggestions

Case analysis: Precautions in laboratory operation

  • Ensure that the instrument is calibrated regularly, especially the selection and adjustment of internal standard elements.
  • Strictly control the purity of reagents to avoid the introduction of external contamination.
  • Pay attention to the safe use of hydrofluoric acid during sample pretreatment. It is recommended to operate in a fume hood.

Sample only — not a preview of GB/T 32650-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend