Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
overhead transmission line introduction overhead transmission lines transmission line operation fault inspection above overhead transmission lines gb/t32673 heat training rooms overhead lines ― composite suspension procument-combined instrument transformerspart
GB/T 32673-2016 in English

GB/T 32673-2016 in English

VALID

Technical guide for fault inspection in overhead transmission line

  • Issued on:2016-04-25
  • Implemented on:2016-11-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 32673-2016
Document status: VALID
Title in English: Technical guide for fault inspection in overhead transmission line
Title in Chinese: 架空输电线路故障巡视技术导则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2016-04-25
Implemented on: 2016-11-01
Professional Classification: GB-National Standard
Related Keywords: overhead transmission line introduction
overhead transmission lines
transmission line operation
fault inspection
above overhead transmission lines gb/t32673
Related Topics: Skyscanner
transmission line
Technical guidelines for prevention and control of bird-related faults on overhead transmission lines
An internal fault causes the
Technical Guidelines for Transmission Line Detection
Patrol
Circuit fault meter
Circuit fault meter
power transmission
Patrol
Patrol
Path failure
/barrier
Line tracer
GBT32673
GB/T 32673-2016
Fault removal device technology

《GB/T 32673-2016架空输电线路故障巡视技术导则》由TC202(全国架空线路标准化技术委员会)归口,TC202SC1(全国架空线路标准化技术委员会线路运行分会)执行,主管部门为中国电力企业联合会。


Introduction

1. Background and significance of the standard

GB/T32673-2016 Technical Guidelines for Fault Inspection of Overhead Transmission Lines is a technical specification for fault inspection of 66kV and above AC and DC overhead transmission lines. The standard aims to improve the safety and reliability of transmission line operation through systematic fault classification, inspection preparation and implementation processes.


2. Comparison of standard frameworks

Standard dimensions GB/T32673-2016 DL/T741-Overhead transmission line operation procedures Comparative analysis
Scope of application 66kV and above AC and DC overhead transmission lines 10kV and above overhead transmission lines GB/T32673 expands the coverage of DC systems
Core content Fault classification, inspection preparation and implementation Line operation management, maintenance and overhaul GB/T32673 focuses more on fault handling process
Technical innovation Introduced lightning strike location system and online monitoring equipment No mention of intelligent monitoring means GB/T32673 is more forward-looking

3. Interpretation of key technologies

Fault classification and cause analysis:The standard divides faults into 10 categories, including ice damage, wind damage, and lightning strikes. Each type of fault has a specific manifestation and identification method.

Case study: Lightning strike fault

In 2017, a 500kV line tripped due to lightning shielding. The fault point was accurately located through the lightning location system, and combined with the burn marks on the tower materials, it was confirmed to be a lightning shielding fault.


4. Implementation Suggestions

  1. Technical equipment upgrade:Equip with advanced online monitoring equipment and lightning location systems to improve fault diagnosis efficiency.
  2. Staff training:Carry out fault inspection skills training regularly, focusing on strengthening emergency response capabilities under complex weather conditions.
  3. Hazard investigation:In accordance with standard requirements, conduct a systematic investigation of potential danger sources such as super-high trees and construction machinery in the line channel.