Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
integrated protection smart substation introduction standard background protection function nari relay protection co. smart substations doors general requirements hydrogeological tests battery zinc
GB/T 32897-2016 in English

GB/T 32897-2016 in English

VALID

General specification for integrated protection and contro1 equipment in smart substation

  • Issued on:2016-08-29
  • Implemented on:2017-03-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $270.00
$262.00

《GB/T 32897-2016智能变电站多功能保护测控一体化装置通用技术条件》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


Introduction

Standard background and evolution

This standard was jointly drafted by 16 units including NARI Relay Protection Co., Ltd. and for the first time systematically standardized the technical system of the integrated protection, measurement and control device in smart substations. Compared with traditional discrete devices, the integrated design achieves:

Comparison dimensionsTraditional devicesIntegrated devices
Functional architectureProtection/measurement and control independent equipmentMulti-function integration
Communication protocolIEC 61850 and conventional hybridFull DL/T 860 standard
Sampling methodConventional CT/PTSupport electronic transformers

Core technical requirements

1. Environmental adaptability

The device needs to work stably in the temperature range of -10℃~+55℃ and the humidity of 5%~95%, and in special areas it can be extended to -25℃~+70℃. Electromagnetic compatibility performance includes:

  • 1MHz pulse group immunity (GB/T 14598.13)
  • Electrostatic discharge immunity (level 3)
  • Radiated electromagnetic field immunity (10V/m)

2. Functional integration requirements

Typical application case: After the integrated device was used in the 35kV line bay of a 110kV substation, the number of cabinets was reduced by 40% and the maintenance hours were reduced by 60%.

The standard specifies that functional modules need to run independently:

  • Protection function: Speed error ≤1% or 40ms
  • Measurement and control function: Telemetry accuracy ±0.2%
  • Merging unit: Sampling value synchronization accuracy ≤1μs

Implementation suggestions

1. Selection considerations

Key parametersStandard requirementsRecommended values
Network storm immunityNo false operation≥1000 frames/second
Timekeeping accuracy≤4μs within 10minPTP protocol is selected

2. Key points of operation and maintenance

Key points:

  1. Relationship between maintenance pressure plate status and GOOSE message quality bit
  2. Regular detection of SV sampling discrete value ≤10μs
  3. Electromagnetic compatibility test retest cycle (recommended 3 years)

Sample only — not a preview of GB/T 32897-2016