GB/T 32936-2016 in English
VALIDMethods of assessing lightning protection within explosion
- Issued on:2016-08-29
- Implemented on:2017-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$146.00
《GB/T 32936-2016爆炸危险场所雷击风险评价方法》由TC345(全国气象防灾减灾标准化技术委员会)归口,主管部门为中国气象局。
Introduction
In-depth interpretation of the risk assessment method for lightning strikes in explosive hazardous places
1. Background and significance of standard formulation
GB/T32936-2016 "Risk Assessment Method for Lightning Strike in Explosive Hazardous Places" is to standardize lightning protection in explosive hazardous places and reduce the risk of explosion accidents caused by lightning strikes. With the rapid development of industrial production, the number and complexity of explosive hazardous places are increasing, and lightning strikes have become a major safety hazard in such places.
2. Comparative analysis of standard frameworks
| Standard dimensions | GB/T32936-2016 | GB/T21714.2-2008 | GB50057-2010 |
|---|---|---|---|
| Scope of application | Lightning risk assessment in explosion-hazardous areas | Risk management of lightning protection of buildings | Design specifications for lightning protection of buildings |
| Core contents | Lightning risk identification, calculation and evaluation methods | Risk management and casualty protection | Classification and design requirements for lightning protection buildings |
| Technical indicators | Calculation of annual lightning strike density, lightning strike risk value, etc. | Loss rate model and protection measures | Lightning protection level classification and rolling ball method formula |
3. Implementation suggestions
Case analysis:Lightning strike risk assessment and protection measures for a petrochemical storage tank area
1. According to GB/T32936-2016, the storage tank area is divided into multiple evaluation units.
2. The annual lightning strike density calculation formula (Ng=0.1×Td) is used to evaluate the regional lightning activity level.
3. Use formula (2) and formula (3) to calculate the lightning strike risk value and safety degree respectively, and determine the key protection areas.
4. Select corresponding protective measures according to the safety L value to ensure that the requirements of the GB/T21714 series standards are met.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 17301-1998 in English
Earth-moving machinery - Operator station and maintenance areas - Bluntness of edges
1998-04-03 -

GB/T 25478-2010 in English
Workstation of chromatography data
2010-12-01 -

GB/T 17489-2022 in English
Hydraulic fluid power—Particulate contamination analysis—Extraction of fluid samples from lines of an operating system
2022-10-12 -

GB/T 11357-2020 in English
Quality, roughness and balance of transmission pulleys
2020-04-28 -

GB/T 31757-2015 in English
Preservative-treated wood decking
2015-07-03 -

GB/T 19665-2024 in English
General specification for infrared imaging measuring and screening instrument of body surface temperature
2024-03-15 -

GB/T 39037.2-2020 in English
Lashing and securing arrangements on road vehicles for sea transportation on Ro/Ro ships—General requirements—Part 2:Semi-trailers
2020-07-21 -

GB/T 21078.1-2023 in English
Financial services—Personal Identification Number(PIN) management and security—Part 1:Basic principles and requirements for PINs in card-based systems
2023-03-17 -

GB/T 35515-2017 in English
Chemicals—Fish assay for oestrogenic and androgenic activity, and aromatase inhibition
2017-12-29 -

GB/T 33347-2016 in English
Reciprocating internal combustion gas generating set- Classification and constituent analysis of gas fuels
2016-12-13