GB/T 3323.2-2019 in English
VALIDNon-destructive testing of welds—Radiographic testing—Part 2:X- and gamma-ray techniques with digital detectors
- Issued on:2019-08-30
- Implemented on:2020-03-01
- File Format:PDF
- Delivery:Via email within 5 business days
$612.00
《GB/T 3323.2-2019焊缝无损检测 射线检测 第2部分:使用数字化探测器的X和伽玛射线技术》由TC55(全国焊接标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
Analysis of the core content of the standard
This standard specifies the technical requirements for X/γ-ray inspection of metal welded joints using CR technology of stored phosphor imaging plates (IP plates) and DR technology of digital array detectors (DDA), with a focus on ensuring that digital inspection achieves the same defect recognition capability as traditional film technology (GB/T3323.1).
Comparison of technical grade systems
| Grade | Applicable scenarios | Sensitivity requirements | Compensation measures |
|---|---|---|---|
| Grade A | Basic detection requirements | Basic image quality meter sensitivity specified in GB/T23901.1/2/5 | Increase grayscale value/SNRN |
| Grade B | High-precision detection | Optimize defect recognition capability | SNRN increased by 1.4 times |
Key Technical Innovations
1. Normalized Signal-to-Noise Ratio (SNRN)
The performance comparison of different detector systems is achieved through the formula SNRN=SNRs×(88.6/SRb), where SRb is the basic spatial resolution.
2. Triple compensation mechanism
- CPⅠ: for contrast loss caused by increased tube voltage
- CPⅡ: compensation for inherent unsharpness of detector
- CPⅢ: correction of local blur caused by bad pixels
Implementation Guide
Detector Selection Recommendations
The CR system should comply with the classification requirements of ISO16371-1, and the DDA system should be regularly calibrated for bad pixels (refer to ASTM E2597). For workpieces with wall thickness>50mm, a microfocus DDA system is recommended.
Optimization of Transillumination Parameters
The geometric magnification M=SDD/SOD should be controlled between 1.0-3.0, and special attention should be paid to the compensation of penetration thickness difference when using Ir192 source (see Appendix B of the standard).
Image quality verification
A dual-line image quality meter (GB/T23901.5) must be used to measure the SRb value. The A-level detection requires CNRN/Δw≥3.5.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 44362-2024 in English
Non-destructive testing of welds—Ultrasonic testing—Automated total focusing technique (TFM)
2024-08-23 -

GB/T 6417.1-2005 in English
Classification and explanation of imperfections in fusion welded joints
2005-08-10 -

GB/Z 41107.3-2021 in English
Destructive tests on welds in metallic materials—Hot cracking tests for weldments—Arc welding processes—Part 3:Externally loaded tests
2021-12-31 -

GB/T 26951-2025 in English
Non-destructive testing of welds—Magnetic particle testing
2025-10-31 -

GB/T 16957-2012 in English
Clad teel plates—Mechanical technical tests on welded joints
2012-12-31 -

GB/T 34628-2017 in English
Non-destructive testing of welds-General rules for metallic materials
2017-10-14 -

GB/T 22085.1-2008 in English
Electron and laser beam welded joints - Guidance on quality levels for imperfactions - Part 1 : Steel
2008-06-26 -

GB/T 29460-2012 in English
Safety assessment for electrofusion joint of polyethylene pipes containing defects
2012-12-31 -

GB/T 2653-2008 in English
Bend test methods on welded joints
2008-03-31