Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
2 3 3 3-tetrafluoropropene content 2 3 3 3-tetrafluoropropene standard items technical indicators industrial use introduction interpretation gb/t33386-2016 industrial industrial applications government departments live flushing operations federated learning method
GB/T 33386-2016 in English

GB/T 33386-2016 in English

VALID

2,3,3,3-Tetrafluoropropene(HFO-1234yf)for industrial use

  • Issued on:2016-12-30
  • Implemented on:2017-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $140.00
$136.00

《GB/T 33386-2016工业用2,3,3,3-四氟丙烯(HFO-1234yf)》由TC63(全国化学标准化技术委员会)归口,主管部门为中国石油和化学工业联合会。


Introduction

Interpretation of GB/T33386-2016 Industrial 2,3,3,3-tetrafluoropropene Standard

Items Technical indicators (superior products) Technical indicators (qualified products)
2,3,3,3-tetrafluoropropene content (w/%) ≥99.8 ≥99.5
Water content (w/%) ≤0.001 ≤0.001
Acidity (as HC l,w/%) ≤0.0001 ≤0.0001
Evaporation residue (w/%) ≤0.005 ≤0.01

Case Study: Application of Gas Chromatography in Content Determination

The content of 2,3,3,3-tetrafluoropropene was determined using a gas chromatograph (with hydrogen flame ionization detector). The measurement accuracy was ensured to be within ±0.1% by standard curve and correction area normalization method. This method is particularly suitable for industrial applications with high purity requirements.