Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
ethoxylate introduction introduction gb/t short-chain tert-octylphenol ethoxylate short chain relative standard deviation various textile products detection horizontal roller scopethis standard machine tool power case technical conditions scopethis standard polyethylene plastic hollow board scopethese regulations
GB/T 33611-2017 in English

GB/T 33611-2017 in English

VALID

Textiles―Determination of short chain 4-(1,1,3,3-tetramethylbutyl) phenol ethoxylate

  • Issued on:2017-05-12
  • Implemented on:2017-12-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $80.00
$78.00
Standard No: GB/T 33611-2017
Document status: VALID
Title in English: Textiles―Determination of short chain 4-(1,1,3,3-tetramethylbutyl) phenol ethoxylate
Title in Chinese: 纺织品 短链对特辛基苯酚乙氧基化物的测定
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-05-12
Implemented on: 2017-12-01
ICS Classification: 59.080.01-Textiles in general
Chinese Classification: W04-Basic standards and general methods
Professional Classification: GB-National Standard
Related Keywords: ethoxylate introduction introduction gb/t
short-chain tert-octylphenol ethoxylate
short chain
relative standard deviation
various textile products detection
Related Topics: Textile short-chain p-tertylphenol ethoxylate
phenoxide
gb t33611 2017
GB/T 33611
Textile Benzene Testing
as33611
GB/T 33611-2017
as 33611
GB/T+33611-2017
phenoxide
GBT33611
GB/T 33611-2017
p-teroctylphenol
phenol textile
Purity test method of o-ethoxyphenol

《GB/T 33611-2017纺织品 短链对特辛基苯酚乙氧基化物的测定》由TC209(全国纺织品标准化技术委员会)归口,TC209SC1(全国纺织品标准化技术委员会基础标准分会)执行,主管部门为中国纺织工业联合会。


Introduction

Introduction

GB/T 33611—2017 "Determination of Short-chain p-tert-octylphenol Ethoxylates in Textiles" is a standard method for the detection of specific chemical substances in textile products in China. This standard specifies the use of normal phase high performance liquid chromatography (HPLC) to determine short-chain p-tert-octylphenol ethoxylates in textiles, including three types: monoethoxylate, diethoxylate and triethoxylate.

Background and significance of standard formulation

As the textile industry continues to increase its requirements for product quality and safety, it has become particularly important to accurately determine the content of specific chemical substances in textiles. As a potential environmental pollutant and a substance that may have an impact on human health, the demand for the detection of short-chain p-tert-octylphenol ethoxylates is becoming increasingly urgent. The formulation of this standard fills the gap in this field in China and provides a scientific basis for the quality control of textile products.

Technical Specification Interpretation

ProjectSpecific content
Scope of applicationDetermination of short-chain 4-tert-octylphenol ethoxylates in various textile products
Detection methodNormal phase high performance liquid chromatography (HPLC)
Instrument requirementsHigh performance liquid chromatograph with fluorescence detector
Extraction solventMethanol, assisted by ultrasonic extraction technology
Quantitative methodExternal standard method

Comparative analysis of standard frameworks

Compared with similar international standards, GB/T 33611—2017 has the following characteristics:

DimensionGB/T 33611Comparison with international standards
Detection objectShort-chain 4-tert-octylphenol ethoxylateSame
Detection methodHPLCConsistent
Precision requirementRelative standard deviation≤10%Internationally accepted level
Lower limit of determination0.5 mg/kgMeets actual detection needs

Implementation suggestions

1. Laboratory conditions:Equipped with high performance liquid chromatography (HPLC) and fluorescence detector, ultrasonic extraction device and rotary evaporator. Laboratory personnel need to undergo professional training.

2. Sample pretreatment steps:Take a representative sample, cut it into 5mm×5mm pieces, weigh 2g of sample and place it in a stoppered conical flask, add 50mL of methanol, and extract it in an ultrasonic generator for 40 minutes. Transfer the extract to a round-bottom flask, wash the residue with 10mL of methanol and combine the extract, concentrate it to nearly 1mL, then make it dilute to 10mL, filter it and test it with HPLC.

3. Quantitative analysis:Quantitative analysis is performed by external standard method using standard working curve. The calculation formula is as follows: $$ X=\frac{(A-A_{\circ})\times c_{\circ}\times V}{A_{\circ}\times m} $$ Where, $X$ is the content of each short-chain tert-octylphenol ethoxylate in the sample (mg/kg).

4. Precision control: The relative standard deviation of the test results within the same laboratory should be ≤10%, and the relative deviation between different laboratories should be ≤20%.

Sample only — not a preview of GB/T 33611-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend