GB/T 34369-2017 in English
VALIDGeneral technical conditions for electrical control device of passenger ropeway
- Issued on:2017-09-29
- Implemented on:2018-04-01
- File Format:PDF
- Delivery:Via email within 5 business days
Price(USD):
$370.00
$359.00
$359.00
| Standard No: | GB/T 34369-2017 |
| Document status: | VALID |
| Title in English: | General technical conditions for electrical control device of passenger ropeway |
| Title in Chinese: | 客运索道电气装置通用技术条件 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2017-09-29 |
| Implemented on: | 2018-04-01 |
| ICS Classification: | 53.040.20-Components for conveyors |
| Professional Classification: | GB-National Standard |
| Related Topics: | General technical requirements for passenger ropeway vehicles
Industrial operating conditions of the device GBT34369 GB/T 34369-2017 DIN6799 Daoke gjb6387 Daoke jgj52 Daoke GB18884.4 Daoke YYT1829 Daoke gjb8875 Daoke Passenger ropeway related |
《GB/T 34369-2017客运索道电气装置通用技术条件》由TC250(全国索道与游乐设施标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
Analysis of the core content of the standard
| Technical module | Key requirements | Safety level |
|---|---|---|
| Power supply system | Dual-circuit/generator backup power supply, voltage fluctuation ±10% | Level 3 |
| Safety circuit | AC25V/DC60V low-voltage design, 500ms anti-malfunction | Level 2 |
| Electromagnetic compatibility | Comply with GB5226.1-2008 4.4.2 | Level 1 |
Key technical requirements
5.4 Drag system stipulates that the main drive device must achieve:
- 0.15-0.5m/s² smooth starting acceleration
- ±5% speed accuracy control
- Four-quadrant operation capability
Typical application case: A high mountain cableway uses ABB ACS880 inverter to achieve torque adaptive control.
Safety protection system
| Hazard type | Protection measures | Test cycle |
|---|---|---|
| Electrical contact | IP22 protection level, safety voltage below 50V | Before daily operation |
| Lightning strike | Station building grounding + wire rope insulation monitoring | Before thunderstorm season |
Implementation suggestions
- Give priority to control equipment certified by GB/T3797
- It is recommended to use Siemens 3SK1 safety relay for the safety circuit
- Establish a three-level maintenance system: daily inspection/monthly inspection/annual inspection