GB/T 34698-2017 in English
VALIDRubber compounding ingredients-Determination of water soluble substance of silica,precipitated,hydrated-Electrolytic conductivity method
- Issued on:2017-11-01
- Implemented on:2018-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
《GB/T 34698-2017橡胶配合剂 沉淀水合二氧化硅水可溶物含量的测定 电导率法》由TC35(全国橡胶与橡胶制品标准化技术委员会)归口,TC35SC5(全国橡胶与橡胶制品标准化技术委员会炭黑分会)执行,主管部门为中国石油和化学工业联合会。
Introduction
GB/T 34698—2017 Standard Overview
This standard specifies the method for determining the water-soluble content in precipitated hydrated silica by the conductivity method, which is applicable to precipitated hydrated silica produced by the sulfuric acid method. Products produced by other production methods can be used as a reference.
Analysis of Standard Formulation Background and Technological Evolution
| Dimension | Traditional Method | Conductivity Method |
|---|---|---|
| Detection Principle | Chemical Titration Method | Relationship between Solution Conductivity and Ion Concentration |
| Operation Complexity | High, requires professional personnel to operate | Relatively simple, with a high degree of automation |
| Detection Accuracy | High | High and good repeatability |
Comparative Analysis of Standard Frameworks
Compared with the traditional chemical titration method, the conductivity method has significantly improved the ease of operation and detection efficiency. The following is a specific comparison:
Case Study: Practical Application of Conductivity Method
Taking the precipitated hydrated silica produced by the sulfuric acid method as an example, the water-soluble content was determined by the conductivity method. The results showed that this method has high accuracy and repeatability. For example, the regression equation calculation example provided in Appendix A shows how to use the standard reference solution to establish a calibration curve and apply it to the determination of actual samples.
Implementation Recommendations
- Equipment Selection:It is recommended to use a conductivity meter equipped with a conductivity electrode with a constant of 1.0 cm⁻¹ to ensure measurement accuracy.
- Sample Preparation:For granulated precipitated hydrated silica samples, they need to be ground in a mortar and passed through a Φ200mm×25mm/0.25mm test sieve.
- Quality Control: Regularly calibrate the instrument to ensure the validity of the regression equation and update the laboratory's regression model according to the company's production situation.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 3778-2021 in English
Carbon black for use in rubber products
2021-10-11