GB/T 35665-2017 in English
VALIDDetermination of formate and acetate in the wet precipitation―Ion chromatography
- Issued on:2017-12-29
- Implemented on:2018-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$214.00
《GB/T 35665-2017大气降水中甲酸根和乙酸根离子的测定 离子色谱法》由TC540(全国气候与气候变化标准化技术委员会)归口,TC540SC1(全国气候与气候变化标准化技术委员会大气成分观测预报预警服务分会)执行,主管部门为中国气象局。
Introduction
Interpretation of GB/T 35665—2017 National Standard of the People's Republic of China
| Standard Framework | Specific Requirements | Implementation Points |
|---|---|---|
| Scope | Applicable to the determination of formate and acetate ion concentrations in atmospheric precipitation samples. | Ensure that sample collection and preservation meet the requirements of GB/T 13580.2. |
| Measurement Principle | Ion exchange is used to separate formate and acetate, and conductivity detector is used for quantitative analysis. | Anion separation column and suppression column are required to ensure stable background signal. |
| Reagent requirements | Standard solutions and test solutions must be accurately prepared, and the eluent should be adjusted according to the instrument instructions. | Deionized water must meet the requirements for conductivity and organic carbon content. |
Overview
This standard was proposed by the China Meteorological Administration to standardize the determination of formate and acetate ions in atmospheric precipitation samples. This standard combines the advantages of ion chromatography and provides a scientific and systematic analysis process.
Measurement principle
Ion chromatography separates formate and acetate ions through an anion exchange column and uses a conductivity detector for quantitative analysis. The key to this method is:
- The configuration of the ion chromatograph, including the suppression column and gradient elution system.
- Establishment of calibration curve ensures good linear relationship (r²≥0.99).
- In the process of sample analysis, test solution and blank sample are interspersed to ensure data reliability.
Reagents and instruments
The standard has strict requirements for reagent preparation:
| Category | Requirements | Precautions |
|---|---|---|
| Standard solution | The concentration of formate and acetate ions is 1000.00 mg/L. | It needs to be stored at 4°C and prepared before use. |
| Eluent | Prepare according to the separation column manual, and the concentration can be fine-tuned appropriately to optimize the separation effect. | It is recommended to configure according to the instrument instructions and replace it regularly. |
Sample Collection and Analysis
Sterilization measures (such as adding chloroform) should be taken immediately after sample collection, and the samples should be analyzed as soon as possible. Before sample analysis, the samples should be filtered through a 0.45 µm filter membrane to remove suspended particles and microbial interference.
Case Study: Analysis of Precipitation Samples in a Certain Region
In actual application, a laboratory measured the concentrations of formate and acetate ions in 10 precipitation samples. The results showed that:
- The average concentrations were 0.85 mg/L (formate) and 1.20 mg/L (acetate).
- The calibration curves were linear, with correlation coefficients above 0.99.
Quality Control and Evaluation
To ensure the accuracy of the analysis results, the standard requires the implementation of the following quality control measures:
- Stability test:Each batch of samples needs to be interspersed with the analysis of the test solution, and it is determined whether the measurement results are within the range of ±20%.
- Precision evaluation:Three test solutions and three precipitation samples were analyzed twice, and the relative standard deviation (RSD) was calculated.
- Accuracy assessment: Use standard samples of known concentration for verification to ensure that the relative deviation is within ±30%.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 33679-2026 in English
Storage conditions for combustion agents and cooling agents used in weather modification
2026-02-27 -

GB/T 44395-2024 in English
Technical specification for reliability evaluation of wind data from lidar
2024-08-23 -

GB/T 31153-2014 in English
Climatic evaluation methods of precipitation resource in the catchment area of small hydropower stations
2014-09-03 -

GB/T 29366-2012 in English
Drought grade of grassland in northern pastoral area
2012-12-31 -

GB/T 42477-2023 in English
Specifications for meteorological observation and data inspection and correction of photovoltaic power stations
2023-03-17 -

GB/T 42072-2022 in English
Climate livability index
2022-10-12 -

GB/T 20486-2026 in English
Grade of watershed areal rainfall
2026-03-31 -

GB/T 32135-2015 in English
Classification of regional drought severity
2015-10-13 -

GB/T 35219-2017 in English
Survey and evaluation methods for surface meteorological observation environment
2017-12-29 -

GB/T 19807-2005 in English
Plastics pipes and fittings--Preparation of test piece assemblies between a polyethylene (PE) pipe and an electrofusion fitting
2004-10-20