Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
system security system security requirements standard security requirement category sl1 protection goal sl4 protection goal key key technical requirements control system industrial control system transformation case static var compensator field tests scopethis standard plate wheel rims new energy efficiency requirements
GB/T 35673-2017 in English

GB/T 35673-2017 in English

VALID

Industrial communication networks—Network and system security—System security requirements and security levels

  • Issued on:2017-12-29
  • Implemented on:2018-07-01
  • File Format:PDF
  • Delivery:Via email within 10 business days
Price(USD): $900.00
$873.00
Standard No: GB/T 35673-2017
Document status: VALID
Title in English: Industrial communication networks—Network and system security—System security requirements and security levels
Title in Chinese: 工业通信网络 网络和系统安全 系统安全要求和安全等级
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 10 business days
Issued on: 2017-12-29
Implemented on: 2018-07-01
Professional Classification: GB-National Standard
Related Keywords: system security system security requirements
standard security requirement category sl1 protection goal sl4 protection goal key
key technical requirements
control system
industrial control system transformation case
Related Topics: Security Level
dmz
Whole network series
network gb
gb network
gb/t35673
GB/T 35673
Industrial Control System Security Level
GBT35673
GB/T 35673-2017
Nuclear power plant digital systems and network security
Prefecture and city network security
Military wireless network security
gb35673
gb 35673-2017

《GB/T 35673-2017工业通信网络 网络和系统安全 系统安全要求和安全等级》由TC124(全国工业过程测量控制和自动化标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Analysis of the core framework of the standard

Security requirement category SL1 protection goal SL4 protection goal Key technical measures
Identity authentication control (IAC) Prevent unintentional access Defense against highly motivated professional attacks Multi-factor authentication, PKI certificate management
Use control (UC) Basic permission restriction Fine-grained access control Role permission mapping, session management
Data confidentiality (DC) Information leakage prevention Advanced decryption resistance Encrypted transmission and storage protection

Detailed explanation of key technical requirements

1. Identity authentication control (IAC)

Core requirements:All personnel, software processes and devices must be authenticated before they can access the control system. Security level (SL) classification:

  • SL1: Basic protection (such as modifying the default password)
  • SL3: Hardware-level key protection is required (TPM module application)
  • SL4: Multi-factor authentication system to defend against APT-level attacks

2. Usage control (UC)

Typical scenario:The operator station needs to be configured with a "double confirmation" mechanism (RE4), and key parameter modification requires double authorization. Wireless device management requirements:

  • SL3+ requires deployment of a wireless intrusion detection system
  • Mobile code requires integrity verification before execution

Implementation suggestions

Refinery industrial control system transformation case

When a refinery’s DCS system was upgraded to SL3:

  1. Deploy hardware security module to protect PLC communication keys
  2. Implement biometric + IC card two-factor authentication at the operator station
  3. Establish an independent audit server to centrally store logs

Note:The SL level of each area must be determined through risk assessment. SIS systems usually require SL4.

Standard Evolution Analysis

This standard is equivalent to IEC 62443-3-3:2013, with the following major developments:

  • 2010 version: proposed 7 basic requirements framework for the first time
  • 2013 version: refined SL level definition and technical requirements
  • 2017 national standard: added Chinese industry implementation guidelines