《GB/T 36137-2018中空纤维超滤膜和微滤膜组件完整性检验方法》由TC382(全国分离膜标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
GB/T 36137—2018 Hollow Fiber Ultrafiltration Membrane and Microfiltration Membrane Component Integrity Test Method Standard Interpretation
1. Background of Standard Formulation and Analysis of Technology Evolution
GB/T 36137—2018 "Hollow Fiber Ultrafiltration Membrane and Microfiltration Membrane Component Integrity Test Method" is one of the important standards in China for separation membranes. The formulation of this standard is based on the rapid development of membrane separation technology, especially its wide application in water treatment, biopharmaceuticals and other industries.
With the advancement of membrane technology, hollow fiber membranes have become the mainstream technology due to their advantages such as high flux and long life. However, the integrity of membrane components is directly related to the separation effect and system reliability, so the requirements for inspection methods are becoming increasingly stringent. This standard aims to unify and standardize inspection methods to ensure the quality control of membrane components.
2. Comparative analysis of standard frameworks
| Standard dimensions | GB/T 36137—2018 | Comparison standards (reference) |
|---|---|---|
| Scope of application | Hollow fiber ultrafiltration membrane and microfiltration membrane assembly | - |
| Core indicators | Integrity inspection by bubble observation method | No clear standard |
| Inspection pressure range | Microfiltration: 0.02~0.05 MPa; ultrafiltration: 0.03~0.10 MPa | - |
3. Recommendations for the implementation of the standard
a) Inspection condition control:Ensure that the inspection environment meets the requirements of normal temperature and sufficient lighting, and the pressure gauge accuracy is not less than 0.4.
b) Appearance inspection priority:Before the bubble observation method, an appearance inspection must be performed first to avoid misjudgment due to obvious defects.
c) Classification inspection strategy:Select the corresponding inspection method and pressure value according to the type of membrane module (online, pressure type, immersion type) to ensure the accuracy of the inspection results.
4. Practical application case analysis
A water treatment company uses GB/T 36137-2018 standard to inspect hollow fiber ultrafiltration membrane modules. Through the bubble observation method, it was found that some membrane components had continuous bubbles during the internal pressure test and were judged as unqualified products. After repair and re-inspection, the qualified rate reached more than 95%.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 37206-2018 in English
Test method for antibacterial properties of organic separation membrane
2018-12-28 -

GB/T 32360-2015 in English
Test methods for ultrafiltration membranes
2015-12-31 -

GB/T 33898-2017 in English
General technical specification for membrane bioreactor
2017-07-12