GB/T 36266-2018 in English
VALIDGlass for shower enclosures
- Issued on:2018-06-07
- Implemented on:2019-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$136.00
| Standard No: | GB/T 36266-2018 |
| Document status: | VALID |
| Title in English: | Glass for shower enclosures |
| Title in Chinese: | 淋浴房玻璃 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2018-06-07 |
| Implemented on: | 2019-07-01 |
| ICS Classification: | 81.040.30-Glass products |
| Chinese Classification: | Q34-Industrial technical glass |
| Professional Classification: | GB-National Standard |
| Related Keywords: | shower room glass
tempered glass film glass tempered film glass glass edge |
| Related Topics: | shower
bath oil GBT36266 GB/T 36266-2018 shower room shower fence Fiberglass sprinkler pipe |
《GB/T 36266-2018淋浴房玻璃》由TC447(全国工业玻璃和特种玻璃标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
National Standard of the People's Republic of China GB/T 36266—2018
Glass for shower enclosures
Background and significance of standard formulation
With the development of the construction industry and the improvement of people's requirements for living comfort, shower enclosures are increasingly used in modern families and public spaces. In order to ensure its safety, durability and functionality, the GB/T 36266—2018 "Glass for shower enclosures" standard came into being. This standard is managed by the National Technical Committee for Standardization of Industrial Glass and Special Glass, covering the full process requirements from material selection to processing technology.
The main drafting units of this standard include Jiangsu Xiu Qiang Glass Technology Co., Ltd., Kangdexin Optical Film Materials (Shanghai) Co., Ltd. and other leading companies in the industry, which fully reflects the advantages of the combination of industry, academia and research. The background of its formulation mainly includes:
- Solving the problem of uneven quality of shower room glass on the market
- Standardizing product classification and performance requirements
- Improving the overall technical level and product quality of the industry
- Adapting to the needs of building safety and intelligent development
Comparative analysis of standard frameworks
| Dimensions | Features of the old standard | Requirements of the new standard | Improvement direction |
|---|---|---|---|
| Classification method | Unclear classification | Divided into laminated glass and tempered film glass according to the processing technology | Increase standardized classification for easy management and testing |
| Safety performance | Only basic strength requirements are specified | New requirements for drop ball impact peeling and shotgun bag impact tests | Improve safety and adapt to higher use environments |
| Environmental protection requirements | Not involved | New requirements for chemical resistance and dirt resistance tests | Promote the development of green building materials |
Explanation of professional terms and practical application cases
Film-mounted tempered glass: refers to composite glass with a functional film attached to the surface of tempered glass. It is mainly used in occasions that require high safety and explosion-proof performance. For example, in high-end hotels and luxury homes, the use of tempered film glass can effectively prevent accidental breakage and reduce the risk of fragmentation.
Laminated glass: Made of two or more pieces of glass with an intermediate material, it has higher strength and safety. For example, in public bathrooms, laminated glass is widely used because of its impact resistance.
Technical Indicators Interpretation
1. Appearance Quality Requirements
- Point defects: diameter ≤0.5mm, 2 points/㎡ allowed; 0.5-1.0mm, 1 point/㎡ allowed
- Line defects: width ≤0.2mm, allowable length 30mm, quantity 4 points/㎡
- Burst edge: length not exceeding 5mm, depth not exceeding 1/3 of thickness
2. Dimension Deviation Requirements
| Side Length Range | Allowable Deviation | Allowable Diagonal Difference Value |
|---|---|---|
| ≤1000mm | ±1.0mm | 2.0mm |
| 1000-2000mm | +2.0,-1.0mm | 2.0mm |
Implementation Recommendations
1. Design Selection Guide
- Choose the appropriate glass type (laminated or tempered film) according to the use environment
- Consider the size of the space and the installation method to determine the glass size
- Give priority to products that have passed national safety certification
2. Construction and Maintenance Recommendations
- Install in strict accordance with standard requirements to avoid damaging the glass edge
- Regularly check the integrity of sealants and fixings
- Avoid heavy impact or high temperature environment during use

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 45543-2025 in English
Substrate glass for organic light emitting diode (OLED) display devices
2025-03-28 -

GB 48005-2026 in English
Safety technical specification of glazing materials for rolling stock
2026-01-28 -

GB/T 29501-2013 in English
Thermal insulation painted glass
2013-05-07 -

GB/T 37991-2019 in English
Measuring method for ultra-thin glass reheating line shrinkage—Dilatometer method
2019-08-30 -

GB/T 37826-2019 in English
Test methods for electrically properties for electrically heated aircraft glass
2019-08-30 -

GB/T 35846-2018 in English
Lighting glass tube for light emitting diode
2018-02-06